OSHA Inspection: SPARTAN LIGHT METAL PRODUCTS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPARTAN LIGHT METAL PRODUCTS LLC in 2510 LAKEVIEW ROAD, MEXICO, MO 65265 (NAICS 336350). OSHA activity number 336666581.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spartan Light Metal Products LLC — free Get an email when a new federal OSHA severe-injury report for Spartan Light Metal Products LLC is published. One employer, no account, unsubscribe in one click.
Site address
2510 LAKEVIEW ROAD
City
MEXICO
State
MO
ZIP
65265
Mailing
2510 LAKEVIEW ROAD, MEXICO, MO 65265
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336350
Employees
283
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 5 exposed
Issued
Oct 31, 2012
Abate by
Dec 14, 2012
Penalty
Initial $5,000 · Current $2,500 Reduced
OSH ACT of 1970 Section (5)(a)(1):     The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an amputation hazard:    Inside of the Die Build-Up Department, the following machines were not equipped with emergency stops:    a/  Bridgeport Milling Machine, Series 1.  b/  Pratt & Whitney Precision Jig Borer, s/n 27181.    One method of abatement to correct this apparent hazard is to install emergency stops as required by ANSI B11.8-2001, paragraph 6.12.3.    DISCLAIMER:    a/  The employer is not limited to the abatement method(s) suggested by OSHA.  b/  The employer is responsible for selecting and implementing an effective abatement method.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

1910.212 A01

Deleted Serious Gravity 5 2 instances 5 exposed
Issued
Oct 31, 2012
Abate by
Dec 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Inside of the Die Build-Up Department, the chucks belonging to the following machines were unguarded:    a/  Bridgeport Milling Machine, Series 1.  b/  Pratt & Whitney Precision Jig Borer, s/n 27181.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 31, 2012
Abate by
Nov 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a/  Inside of the Die Build-Up Department, the Dayton Vertical Sander, unknown m/n or s/n was unguarded.  The exposed portion of the abrasive surface measured approximately 12 inches in diameter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 B

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 31, 2012
Abate by
Nov 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b):     Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a/  Inside of the Die-Build-Up Area, the Dayton Dual Buffer Machine, s/n 1Z909E, was not bolted to the concrete floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 E02

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 31, 2012
Abate by
Nov 1, 2012
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.23(e)(2):     Stair rails did not consist of a top rail, intermediate rail and/or posts, with the vertical height not more than 34 inches (86.36 cm) nor less than 30 inches (76.2 cm) from upper surface of top rail to surface of tread in line:    a/  At the Magniesium Die Cast Cell #12, the stairrail was missing a mid-rail.  The flight of stairs consisted of nine risers.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4000

1910.147 C06 II

Other-than-serious 120 instances 200 exposed
Issued
Oct 31, 2012
Abate by
Dec 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):     The employer did not certify that periodic inspections of the energy control procedures had been performed:    Periodic inspection of the lockout/tagout procedures were not certified for the following machinery:    a/  Die-Cast Machine #2.  b/  Magneisium Die Cast.  c/  CNC Lathes.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E01

Other-than-serious 1 instance 4 exposed
Issued
Oct 31, 2012
Abate by
Dec 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(1):     The employer was responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:    a/  Inside of the Magna Machining Department, a portable ABC rated fire extinguisher was missing both its pin and inspection tag.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV D

Other-than-serious 2 instances 4 exposed
Issued
Oct 31, 2012
Abate by
Dec 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D):     Flexible cords were attached to building surfaces:    a/  Inside of the South 7 Department, a yellow, flexible cord was wrapped around a support column.  The flexible cord provided power to a fluorescent light.    b/  Inside of the Die Cast Machine #1, a black, flexible cord was wrapped around a support column and laid across a overhead, metal walking surface.  The flexible cord provided power to a fluorescent light.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0