Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: T & R FIXTURES, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of T & R FIXTURES, LLC in 210 COMMERCE DRIVE, DALLAS, GA 30132 (NAICS 321918). OSHA activity number 336681218.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T & R Fixtures, LLC — free Get an email when a new federal OSHA severe-injury report for T & R Fixtures, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
T & R FIXTURES, LLC
Site address
210 COMMERCE DRIVE
City
DALLAS
State
GA
ZIP
30132
Mailing
210 COMMERCE DRIVE, DALLAS, GA 30132
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.95(c)(1):     The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    a) The employee operating the Weeke #2 was exposed to noise levels at 67.17% of the action level dose (8-hour time weighted average sound level of 85 decibels) or an equivalent sound level of 87.13 dBA during 455 minute sampling period on October 16, 2012, exposing the employee to noise induced hearing loss.    b) The employee operating the Nestek was exposed to noise levels at 73.60% of the action level dose (8-hour time weighted average sound level of 85 decibels) or an equivalent sound level of 87.79 dBA during 414 minute sampling period on October 16, 2012, exposing the employee to noise induced hearing loss.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Nov 14, 2012
Abate by
Jan 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1):     The employer did not ensure that a written respiratory protection program with worksite-specific procedures was established and implemented to include the provisions of (i)-(ix), as applicable:    a)  The employer did not established or implemented a respiratory protection program for the employees required to wear a MSA half mask respirator while working in the paint booth. There was no written program, medical evaluations, fit-testing, or training provided to employees, exposing employees to upper respiratory irritations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View T & R Fixtures, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336681218.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.