OSHA Inspection: T & R FIXTURES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of T & R FIXTURES, LLC in 210 COMMERCE DRIVE, DALLAS, GA 30132 (NAICS 321918). OSHA activity number 340579978.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T & R Fixtures, LLC — free Get an email when a new federal OSHA severe-injury report for T & R Fixtures, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
T & R FIXTURES, LLC
Site address
210 COMMERCE DRIVE
City
DALLAS
State
GA
ZIP
30132
Mailing
210 COMMERCE DRIVE, DALLAS, GA 30132
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
32
Ownership type
A

5 citations on file for this inspection.

1910.22 A01

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Jul 13, 2015
Abate by
Jul 30, 2015
Penalty
Initial $5,390 · Current $0 Reduced

Hazardous substances E200

29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean.      a) Production Area: The employer failed to ensure that the floor, piping, walls and equipment remained free from the accumulation of combustible wood dust. Employees were exposed to a fire/explosion hazard while performing duties involving the cutting of wood pieces for the manufacture of wood shelves. A sample taken on April 23, 2015 was determined to be a CLASS II combustible dust.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5390

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Jul 13, 2015
Penalty
Initial $5,390 · Current $2,695 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     a)  Production Area - The employer failed to develop, document, and utilize a lockout procedure for employees performing duties involving jammed wood and/or laminate. On or about May, 20, 2015 the electrical disconnect on the Holzma CNC; model HPL 11 was not locked out prior to an employee attempting to remove a jam and/or miss fed piece of laminate.
Recent events (2)
  • — I (S) $2695
  • — Z (S) $5390

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Jul 13, 2015
Abate by
Jul 23, 2015
Penalty
Initial $5,390 · Current $3,234 Reduced

Hazardous substances E200

29 CFR 1910.242(b): Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.     a) Production Area: The employer failed to ensure that compressed air utilized for cleaning was reduced to less than 30 PSI. Employees were allowed to utilized compressed air for cleaning at an operating pressure above 80 PSI while performing saw operations for the manufacture of wood shelves.
Recent events (2)
  • — I (O) $3234
  • — Z (S) $5390

1910.307 C

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Jul 13, 2015
Abate by
Aug 27, 2015
Penalty
Initial $5,390 · Current $0 Reduced

Hazardous substances E200

29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location   Production Area: The employer failed to ensure that all electrical equipment operated in the area was approved for a DIVISION 1, CLASS II location. Employees were exposed to a fire/explosion hazard while sawing, sanding, and performing various activities for the manufacture of wood shelves. A sample taken on April 23, 2015 was determined to be a Division I CLASS II explosive combustible dust.         a) Florescent lighting in the area was not explosion proof lighting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5390

1910.1200 H01

Other-than-serious 1 instance 5 exposed
Issued
Jul 13, 2015
Abate by
Jul 30, 2015
Penalty
Initial $5,390 · Current $3,234 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area.     a) T & R Fixtures: The employer failed to provide training on hazard communication program for employees exposed to materials such as, but not limited to, combustible dust while performing assigned duties involving the manufacture of wood products.
Recent events (2)
  • — I (O) $3234
  • — Z (S) $5390

View T & R Fixtures, LLC's full OSHA safety record →