BOSTON, MA —
OSHA Inspection: S & F CONCRETE CONTRACTORS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of S & F CONCRETE CONTRACTORS, INC. in 75 EXETER STREET, BOSTON, MA 02119 (NAICS 238110). OSHA activity number 337461818.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S & F CONCRETE CONTRACTORS, INC.
- Site address
- 75 EXETER STREET
- City
- BOSTON
- State
- MA
- ZIP
- 02119
- Mailing
- 160 MAIN STREET, HUDSON, MA 01749
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.150 C01 VI
- Issued
- Mar 21, 2013
- Abate by
- Apr 2, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles. Jobsite: Contractor was storing Aceteylene bottles in exposed cage along with storing (4) four 5-gallon containers of gas with no fully charged fire extinguishers within 50 feet.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.350 A10
- Issued
- Mar 21, 2013
- Abate by
- Mar 29, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. Jobsite: Oxygen/Aceteylene bottles were stored on lower level of the project (the pit) next to (4) four 5-gallon containers of gasoline used to power the portable generators.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.701 B
- Issued
- Mar 21, 2013
- Abate by
- Mar 29, 2013
- Penalty
- Initial $5,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement. Jobsite: Base footings / columns had exposed rebar exposing employees to slips trips falls and punctures from not putting protective covers over (5) five different locations on base level. S & F Concrete was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.701(b), which was contained in OSHA inspection number 313554008, citation number 1, item number 2 and was affirmed as a final order on 08/24/09, with respect to a workplace located at 134 Boston Post Road Weston, Ma.
Recent events (2)
- — I (R) $0
- — Z (R) $5600
More inspections at S & F Concrete Contractors, INC.
View S & F Concrete Contractors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337461818.