BESSEMER, AL —
OSHA Inspection: DBI, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of DBI, INC. in 3031 DUBLIN CIRCLE, BESSEMER, AL 35022 (NAICS 337110). OSHA activity number 337551410.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DBI, INC.
- Site address
- 3031 DUBLIN CIRCLE
- City
- BESSEMER
- State
- AL
- ZIP
- 35022
- Mailing
- 3031 DUBLIN CIRCLE, BESSEMER, AL 35022
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 14
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.107 B05 I
- Issued
- Dec 28, 2012
- Abate by
- Jan 18, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): Spraying operations were not designed, installed and maintained so that the average air velocity over the open face of the booth (or booth cross section during spraying operations) was not less than 100 linear feet per minute; visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity was being maintained; and /or filter rolls were not inspected to insure proper replacement of filter media: (a) On or about November, 27, 2012 - Paint Booth, the manometer located in the spray booth was not operable. (b) On or about November 27, 2012 - Paint Booth, residue of paint had accumulated in the filters.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.134 C01
- Issued
- Dec 28, 2012
- Abate by
- Feb 2, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about November 27, 2012 - Facility, a written respiratory program had not been developed and implemented for employees required to wear respirators such as, but not limited to, 3M half-facepiece respirators.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.134 E01
- Issued
- Dec 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about November 27, 2012 - Facility, medical evaluations were not provided to employees required to wear respirators such as, but not limited to, 3M half-facepiece respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Dec 28, 2012
- Abate by
- Feb 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done: (a) On or about November 28, 2012 - Facility, no written certification to verify the hazard assessment had been performed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F01
- Issued
- Dec 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) On or about November 27, 2012 - Facility, fit tests were not provided to employees required to wear respirators such as, but not limited to, 3M half-facepiece respirators.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DBI, INC.
View DBI, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337551410.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.