Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOMENTIVE PERFORMANCE MATERIALS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MOMENTIVE PERFORMANCE MATERIALS in 260 HUDSON RIVER RD HYDROGEN TANKS, WATERFORD, NY 12188 (NAICS 325199). OSHA activity number 337732226.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Momentive Performance Materials — free Get an email when a new federal OSHA severe-injury report for Momentive Performance Materials is published. One employer, no account, unsubscribe in one click.
Site address
260 HUDSON RIVER RD HYDROGEN TANKS
City
WATERFORD
State
NY
ZIP
12188
Mailing
260 HUDSON RIVER RD, WATERFORD, NY 12188
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325199
Employees
1140
Ownership type
A

4 citations on file for this inspection.

1910.119 E03 III

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2013
Abate by
Jul 6, 2013
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.119(e)(3)(iii): The process hazard analysis did not address engineering and administrative controls applicable to the hazards and their interrelationships such as appropriate application of detection methodologies to provide early warning of releases.    A) Hydrogen Storage Area - On and prior to December 7, 2012, the 2011 process hazard analysis did not address the engineering and administrative controls which would be used to detect hydrogen fires, in that existing detection methodology did not allow and/or consider detection of a release involving hydrogen combustion.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.119 J04 IV

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2013
Abate by
Jul 6, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.119(j)(4)(iv):   The employer did not document the date of inspection, the name of the person performing the inspection, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection, and the results of the inspection for each piece of process equipment.  A) Hydrogen Tank Area - On or prior to December 7, 2012, the host employer did not maintain documentation of mechanical integrity inspections performed by the contractor, Praxair, Inc.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.119 J02

Deleted Repeat Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2013
Abate by
Jul 6, 2013
Penalty
Initial $38,500 · Current $0 Reduced
29 CFR 1910.119(j)(2):   The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment:  A) Hydrogen Tank Area - On or prior to December 7, 2012, written mechanical integrity procedures were not established or implemented for the following:  -Maintenance of Liquid Hydrogen Storage Tank #1, Liquid Hydrogen Storage Tank #2, Steam Vaporizers and all associated piping and instrumentation, including but not limited to: flanges, valves, and detectors.  -Inspections of Liquid Hydrogen Storage Tank #1, Liquid Hydrogen Storage Tank #2, Steam Vaporizers and all associated piping and instrumentation, including but not limited to: flanges, valves, and detectors.   Momentive Performance Materials was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.119(j)(2), which was contained in OSHA inspection number 313763666, citation number 1, item number 4 and was affirmed as a final order on August 24, 2012, with respect to a workplace located at 260 Hudson River Rd. Waterford, NY 12188.
Recent events (3)
  • — F (R) $0
  • — C (R) $38500
  • — Z (R) $38500

1910.119 J04 III

Deleted Repeat Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2013
Abate by
Jul 6, 2013
Penalty
Initial $38,500 · Current $0 Reduced
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience.  A) Hydrogen Tank Area - On or prior to December 7, 2012, the frequency of inspections and tests was not determined for the hydrogen system process equipment, including but not limited to:   -All associated liquid and gas piping, seals, flanges, valves, fittings, and supports -All leak detection and control instrumentation  Momentive Performance Materials was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.119(j)(4)(iii), which was contained in OSHA inspection number 313763666, citation number 1, item number 5 and was affirmed as a final order on August 24, 2012, with respect to a workplace located at 260 Hudson River Rd. Waterford, NY 12188.
Recent events (3)
  • — F (R) $0
  • — C (R) $38500
  • — Z (R) $38500