OSHA Inspection: PARKER RUST PROOF OF CLEVELAND, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PARKER RUST PROOF OF CLEVELAND, INC. in 1688 ARABELLA RD., CLEVELAND, OH 44112 (NAICS 332812). OSHA activity number 337957021.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Parker Rust Proof of Cleveland, INC. — free Get an email when a new federal OSHA severe-injury report for Parker Rust Proof of Cleveland, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1688 ARABELLA RD.
City
CLEVELAND
State
OH
ZIP
44112
Mailing
1688 ARABELLA RD., CLEVELAND, OH 44112
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
38
Ownership type
A

5 citations on file for this inspection.

1910.22 B01

Other-than-serious 1 instance 38 exposed
Issued
Mar 1, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.22(b)(1): Where mechanical equipment is used aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard:    On or about December 20, 2012, the employer did not keep the passageway between the Barrel Line and material area in good repair. Employees operate mechanical equipment between the two areas.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3500

1910.95 C01

Serious Gravity 10 1 instance 38 exposed
Issued
Mar 1, 2013
Abate by
May 30, 2013
Penalty
Initial $4,900 · Current $4,200 Reduced
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program, as described in paragraphs (c) through (o) of this section, whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level (TWA) of 85 decibels measured on the A scale (slow response) or, equivalently, a dose of fifty percent:    a) The employer had not developed and implemented a hearing conservation program for employees expsoed to 8-hour time-weighted average (TWA) sound levels of 85 dBA or greater (50% dose). An employee working on the barrel line was exposed to continuous noise at 91.0% of the permissible daily noise exposure during the 443 minute sampling period on 2/14/2013; exposure calculations include a zero increment for the 37 minutes not sampled.    b)The employer had not developed and implemented a hearing conservation program for employees expsoed to 8-hour time-weighted average (TWA) sound levels of 85 dBA or greater (50% dose). An employee working on the barrel line was exposed to continuous noise at 87.9% of the permissible daily noise exposure during the 439 minute sampling period on 2/14/2013; exposure calculations include a zero increment for the 41 minutes not sampled.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $4900

1910.22 D01

Other-than-serious 1 instance 38 exposed
Issued
Mar 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked in a conspicuous place in each space to which they related:    On or about December 20, 2012, the employer did not load rate the overhead storage area in manufacturing department.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K06

Other-than-serious 1 instance 38 exposed
Issued
Mar 1, 2013
Abate by
Mar 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:    On or about December 20, 2012, employees were voluntarily wearing N-95 filtering face piece respirators while working near acid tanks and the employer did not provide employees with Appendix D of the respiratory standard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.141 D02 II

Other-than-serious 1 instance 38 exposed
Issued
Mar 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water:    On or about December 20, 2012, the employer did not have hot water in the mens locker room.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Parker Rust Proof of Cleveland, INC.'s full OSHA safety record →