ANCHORAGE, AK —
OSHA Inspection: HORIZON LINES OF ALASKA LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HORIZON LINES OF ALASKA LLC in 1717 TIDEWATER ROAD, ANCHORAGE, AK 99501 (NAICS 488320). OSHA activity number 337959423.
Where did this inspection happen?
- Establishment
- HORIZON LINES OF ALASKA LLC
- Site address
- 1717 TIDEWATER ROAD
- City
- ANCHORAGE
- State
- AK
- ZIP
- 99501
- Mailing
- 1717 TIDEWATER ROAD, ANCHORAGE, AK 99501
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488320
- Employees
- 65
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.303 G02 I
- Issued
- Penalty
- Initial $2550.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i). Maintenance Shop, Wash Rack, Soap Mixing Room: On or about 19 December 2012 and times prior thereto, the 120 volt electrical junction box missing was a cover plate. This condition exposed employees to an electrical shock hazard.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1910.305 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. (a) Chassis shop, middle row: On or about 19 December 2012 and times prior thereto, the extension cord roller exhibited strain relief on the electrical plug exposing wires. This condition exposed employees to a 120 volt electrical shock hazard. (b) Chassis shop, south bay area: On or about 19 December 2012 and times prior thereto, the extension cord roller exhibited strain relief on the electrical plug exposing wires. This condition exposed employees to a 120 volt electrical shock hazard. (c) Maintenance shop, Reefer repair area: On or about 19 December 2012 and times prior thereto, the reefer cord exhibited strain relief on the electrical plug exposing wires. This condition exposed employees to a 120 volt electrical shock hazard. (d) Maintenance shop, Wash rack bay: On or about 19 December 2012 and times prior thereto, the blue light assembly exhibited strain relief on the electrical plug exposing wires. This condition exposed employees to a 120 volt electrical shock hazard.
Recent events (1)
- — Z (S) $0
1910.334 A02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). a) Chassis shop, middle row: On or about 19 December 2012 and times prior thereto, a portable grinder was missing a ground pin. This condition exposed employees to a 120 volt electrical shock hazard. (b) Maintenance shop: On or about 19 December 2012 and times prior thereto, the extension cord roller female end in had evidence of burn through. This condition exposed employees to a 120 volt electrical shock hazard. (c) Maintenance shop, hand tool storage: On or about 19 December 2012 and times prior thereto, the Milwaukee saw was missing a ground pin. This condition exposed employees to a 120 volt electrical shock hazard.
Recent events (1)
- — Z (S) $0
1917.122 D
- Issued
- Penalty
- Initial $2550.00 · Current $2550.00
General-duty citation text
29 CFR 1917.122(d): The minimum width of any employee exit shall be 28 inches (71.12 cm). Chassis shop, old boiler room: On or about 19 December 2012 and times prior thereto, the exit door would only open to twenty inches. This condition exposed employees to smoke inhalation and/or fire hazards from delays in exiting the building.
Recent events (2)
- — I (O) $2550
- — Z (S) $2550
1917.152 E02 II
- Issued
- Penalty
- Initial $2550.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1917.152(e)(2)(ii): Arc welding or cutting cable was used when it was not free from repair or splice for 10 feet (3 m) from the electrode holder. Maintenance shop: On or about 19 December 2012 and times prior thereto, the Thermal Dynamics Professional welder #18 had a stinger with exposed wires covered with common black electrical tape. This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1917.154
- Issued
- Penalty
- Initial $2550.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1917.154: Employees shall be protected by chip guarding and personal protective equipment complying with the provisions of Subpart E of this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a pressure of 30 psi. Compressed air shall not be used to clean employees. Maintenance shop: On or about 19 December 2012 and times prior thereto, employee was using an air nozzle without appropriate 30 PSI deflection tip installed. Shop air was measure at approximately 120 PSI. This condition exposed employees to air embolism/laceration hazards if they contacted their skin.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1917.152 C03
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1917.152(c)(3): Fire extinguishing equipment suitable for the location was not immediately available or maintained in readiness for use at all times during the performance of hot work. Chassis and Maintenance shop area: On or about 19 December 2012 and times prior thereto, the fire extinguishers in the chassis shop and two in the maintenance shop were overdue on their monthly inspections. This exposed employees to burn hazards.
Recent events (1)
- — Z (O) $0
More inspections at HORIZON LINES OF ALASKA LLC
KODIAK, AK—2014-08-12 00:00:00
HORIZON LINES OF ALASKA, LLC
KODIAK, AK—2014-08-12 00:00:00
HORIZON LINES OF ALASKA, LLC
ANCHORAGE, AK—2014-03-11 00:00:00
HORIZON LINES OF ALASKA LLC
ANCHORAGE, AK—2012-12-26 00:00:00
HORIZON LINES OF ALASKA, LLC
ANCHORAGE, AK—2012-12-19 00:00:00
HORIZON LINES OF ALASKA LLC
View HORIZON LINES OF ALASKA LLC's full OSHA safety record →
More inspections in this industry (NAICS 488320)
MARATHON, FL—2026-07-14 00:00:00
DISCOUNT ROCK & SAND, INC.
RIVIERA BEACH, FL—2026-07-07 00:00:00
PORT CONTRACTORS SOUTHEAST, LLC
JACKSONVILLE, FL—2026-07-01 00:00:00
CROWLEY LINER SERVICES
SEATTLE, WA—2026-06-30 00:00:00
WA317991873 - SSA TERMINALS LLC
TERMINAL ISLAND, CA—2026-06-10 00:00:00
YUSEN TERMINALS LLC
More inspections in AK
ANCHORAGE, AK—2026-07-10 00:00:00
AK, INC
ANCHORAGE, AK—2026-07-08 00:00:00
ONE STOP SERVICES
ANCHORAGE, AK—2026-07-08 00:00:00
ANGUS ENTERPRISES
ANCHORAGE, AK—2026-07-08 00:00:00
NORTHERN EXCAVATION & CONSTRUCTION, LLC
UNALASKA, AK—2026-07-07 00:00:00
UNISEA INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337959423.