SAINT JOHN, KS —
OSHA Inspection: MAVERICK DRILLING, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAVERICK DRILLING, LLC. in SEC 36, TWP 24, R 14, 330 FNL, 1650 FWL, SAINT JOHN, KS 67576 (NAICS 213111). OSHA activity number 338174816.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAVERICK DRILLING, LLC.
- Site address
- SEC 36, TWP 24, R 14, 330 FNL, 1650 FWL
- City
- SAINT JOHN
- State
- KS
- ZIP
- 67576
- Mailing
- 100 S MAIN ST. SUITE 440, WICHITA, KS 67202
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 7, 2013
- Abate by
- Apr 23, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: Employees working at the drilling rig located at SEC 32, TWP 19, R 9, 990 fsl, 440 fwl, Chase, Kansas were exposed to struck-by hazards. The employer had not done inspections of the hoisting equipment to ensure their safe operations. Among other methods, one feasible and acceptable method is to conduct and record inspections of hoisting equipment as stated in American Petroleum Institute (API) Recommended Practice for Procedures for Inspections, Maintenance, Repair, and Remanufacture of Hoisting Equipment, 1997 edition, paragraph 1.3 Procedure Development. "The owner and user together with the manufacturer should jointly develop and update inspection, maintenance, repair and remanufacture procedures consistent with equipment application, loading, work environment, usage, and other operational conditions."
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.24 C
- Issued
- Mar 7, 2013
- Abate by
- Apr 2, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.24(c): Fixed stairway(s) were not designed and/or constructed to carry a load of five times the normal live load anticipated or the strength to carry safely a moving load of 1000 pounds: Employees using the stairs to the doghouse at the drilling rig location SEC 32, TWP 19, R 9, 990 fsl, 440 fwl, Chase, Kansas were exposed to slip and trip hazards in that 7th stair tread was broken away from the runner causing the stair flex.
Recent events (2)
- — I (O) $1050
- — Z (S) $2100
1910.305 B01 II
- Issued
- Mar 7, 2013
- Abate by
- Apr 2, 2013
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Employees working in the generator trailer at the drilling rig location SEC 32, TWP 19, R 9, 990 fsl, 440 fwl, Chase, Kansas were exposed to electrical shock hazards. There was a missing 220 Volt AC breaker in the main electrical panel exposing live electrical components.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.24 H
- Issued
- Mar 7, 2013
- Penalty
- Initial $17,500 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: Employees using the stairs at the drilling rig located at SEC 32, TWP 19, R 9, 990 fsl, 440 fwl, Chase, Kansas from were exposed to fall hazards of approximately 8 feet to the ground in that the handrail for the fixed industrial stairs from the drill deck to the pipe rack was not installed. Maverick Drilling, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.24(h), which was contained in OSHA inspection number 315086223, citation number 01, item number 001 and was affirmed as a final order on 04/19/2011, with respect to a workplace located at SEC 24, TWP 26, R 12, Preston, Kansas. Maverick Drilling, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.24(h), which was contained in OSHA inspection number 312801566, citation number 01, item number 003 and was affirmed as a final order on 09/14/2009, with respect to a workplace located at SEC 23, TWP 10, R 15, Natoma, Kansas.
Recent events (2)
- — I (R) $3500
- — Z (R) $17500
More inspections at Maverick Drilling, LLC.
View Maverick Drilling, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338174816.