SAN MARCOS, TX —
OSHA Inspection: HELDENFELS ENTERPRISES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HELDENFELS ENTERPRISES, INC. in 5700 IH 35 SOUTH, SAN MARCOS, TX 78666 (NAICS 327310). OSHA activity number 338228414.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HELDENFELS ENTERPRISES, INC.
- Site address
- 5700 IH 35 SOUTH
- City
- SAN MARCOS
- State
- TX
- ZIP
- 78666
- Mailing
- 5700 IH 35 SOUTH, SAN MARCOS, TX 78666
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327310
- Employees
- 175
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Apr 19, 2013
- Abate by
- Jul 23, 2013
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) on all open sides: On or about January 11, 2013, the employer did not provide a complete fall protection system while employees were performing duties from the form platforms, exposing employees to a fall hazard up to 5 feet.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.254 D09 III
- Issued
- Apr 19, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced: On or about January 11, 2013, and at times prior thereto, the employer did not ensure arc welding cables were free of damage to the insulation, exposing the employees to the hazard of heated conductors and electrical shock.
Recent events (2)
- — I (S) $1377
- — Z (S) $2295
1904.29 B01
- Issued
- Apr 19, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(b)(1): A log of all recordable work-related injuries and illness (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation: For the 2011 and 2012 OSHA 300 Logs, incomplete descriptions in column (F) on the Logs materially impaired understandability of the nature of the hazard, injuries and illnesses in the workplace in instances such as but not limited to: a) The specific body part affected was not recorded on almost all of 2011 cases and 2012 case #1. b) The object/subtance that directly injured ot made the person ill was not recorded for all cases 2011 and 2012 cases #1,5, 20 and 28.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Heldenfels Enterprises, INC.
View Heldenfels Enterprises, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338228414.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.