On , OSHA opened a planned safety inspection of SHELBY MANUFACTURING in 633 NORTH CLAY STREET, GLENWOOD, AR 71943 (NAICS 315992). OSHA activity number 338429632.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SHELBY MANUFACTURING
- Site address
- 633 NORTH CLAY STREET
- City
- GLENWOOD
- State
- AR
- ZIP
- 71943
- Mailing
- 633 NORTH CLAY STREET, GLENWOOD, AR 71943
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 315992
- Employees
- 64
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.215 A04
- Issued
- May 7, 2013
- Abate by
- May 9, 2013
- Penalty
- Initial $3,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: On or about January 23, 2013, at the Shelby Manufacturing facility in Glenwood, Arkansas, the employer did not ensure work rests on grinding machinery were adjusted closely to the wheel with a maximum 1/8 inch opening exposing employees to caught in hazards in the following: a) The left end of the Skill grinder in the maintenance shop. b) The right end of the Skill grinder in the maintenance shop.
Recent events (2)
- · I (S) $1000
- · Z (S) $3000
1910.215 B09
- Issued
- May 7, 2013
- Abate by
- May 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about January 23, 2013, at the Shelby manufacturing facility in Glenwood, Arkansas, the employer allowed the distance between the abrasive wheels's periphery and the adjustable tongue to exceed 1/4 inch exposing employees to the hazard of being struck by flying particles in the following: a) The left end of the Skill bench grinder in the maintenance shop. b) The right end of the Skill bench grinder in the maintenance shop.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.242 B
- Issued
- May 7, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $3,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about January 23, 2012, a the Shelby Manufacturing facility in Glenwood, Arkansas, the employer did not reduce compressed air used for cleaning purposes to less than 30 p.s.i.g. exposing employees to the hazard of being struck by flying particles or cut by air stream contact.
Recent events (2)
- · I (S) $1000
- · Z (S) $3000
1910.303 B07 IV
- Issued
- May 7, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $3,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: On or about January 23, 2013, at the Shelby Manufacturing facility in Glenwood, Arkansas, the employer allowed the use of damaged parts that could adversely affect the safe operation of the equipment, exposing employees to the hazard of electric shock.
Recent events (2)
- · I (S) $1000
- · Z (S) $3000
1910.305 B02 I
- Issued
- May 7, 2013
- Abate by
- May 15, 2013
- Penalty
- Initial $5,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about January 23, 2013, at the Shelby Manufacturing facility in Glenwood, Arkansas, the employer did not ensure outlet boxes in completed installations had covers, faceplates, or fixture canopies, exposing employees to the hazard of electric shock and fire hazards.
Recent events (2)
- · I (S) $2000
- · Z (S) $5000
1910.147 C06 I
- Issued
- May 7, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about January 23, 2013, at the Shelby Manufacturing facility in Glenwood, Arkansas, the employer did not perform a periodic inspection of the energy control program, at least annually, exposing employees to the hazard of being caught in the machines.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 B02
- Issued
- May 7, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about January 23, 2013, at the Shelby Manufacturing facility in Glenwood, Arkansas, the employer did not ensure listed or labeled electrical equipment was used in accordance with its listing or labeling, exposing employees to fire hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 G01 IV A
- Issued
- May 7, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about January 23, 2013, a the Shelby Manufacturing facility in Glenwood, Arkansas, the employer used a flexible cord as a substitute for the fixed wiring of the structure exposing employees to burn hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Shelby Manufacturing
View Shelby Manufacturing's full OSHA safety record →
More inspections in this industry (NAICS 315992)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338429632.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.