STURGEON BAY, WI —
OSHA Inspection: EXACTECH, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EXACTECH, INC in 107 E. WALNUT STREET, STURGEON BAY, WI 54235 (NAICS 332312). OSHA activity number 338449630.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EXACTECH, INC
- Site address
- 107 E. WALNUT STREET
- City
- STURGEON BAY
- State
- WI
- ZIP
- 54235
- Mailing
- 107 E. WALNUT STREET, STURGEON BAY, WI 54235
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 78
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 D01 III
- Issued
- Feb 22, 2013
- Abate by
- Mar 27, 2013
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: a) The employer had not conducted air monitoring in the paint booth to determine the exposure to the painter(s) and the appropriate type of respirator required for painter(s) using Two Component Buff Epoxzen Primer. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.134 F02
- Issued
- Feb 22, 2013
- Abate by
- Mar 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting face piece respirator were not annually fit tested: a) Employer had not performed the annual respirator fit testing for the painter who used a 3M full face piece respirator for painting in the paint shop using Two Component Buff Epoxzen Primer. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- Feb 22, 2013
- Abate by
- Mar 27, 2013
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) A welder that used a lift truck daily was not included with in the re-test of lift truck operators that occurred every three years. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.184 H05 III
- Issued
- Feb 22, 2013
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.184(h)(5)(iii): Natural or synthetic fiber rope sling(s) with broken or cut fibers were not immediately removed from service: a) In Bay #2 west, slings were available for use to lift heavy metal parts with broken or cut fibers. Red warning fibers were showing on the damaged areas of the slings. NO ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.184 I01
- Issued
- Feb 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material: a) In Bay #1, slings were observed available for use to lift heavy metal parts without markings to show rated capacities. NO ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.25 D02 VIII
- Issued
- Feb 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.25(d)(2)(viii): Ladders with broken or missing steps, rungs, or cleats, broken side rails, or other faulty equipment were used; a) In Bay #5, a five foot wooden step ladder was used with a broken bottom step and split side rails. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION NOT REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Exactech, INC
View Exactech, INC's full OSHA safety record →