Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RADFORD & RADFORD INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RADFORD & RADFORD INC. in 600 RIVER ROAD, PINEVILLE, WV 24874 (NAICS 236220). OSHA activity number 338550437.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Radford & Radford INC. — free Get an email when a new federal OSHA severe-injury report for Radford & Radford INC. is published. One employer, no account, unsubscribe in one click.
Site address
600 RIVER ROAD
City
PINEVILLE
State
WV
ZIP
24874
Mailing
PO BOX 1857, BECKLEY, WV 25802
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
23
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 1, 2013
Penalty
Initial $2,380 · Current $2,380
29 CFR 1926.100(a):     Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a. Hallway to Section A / Corridor 200: Employees were not wearing hard hats while working from the lower level on the scaffold while other employees were loading the the top level of the 9 feet 9 inch tall fabricated frame scaffold with masonry blocks as observed on 1-29-13.
Recent events (1)
  • — Z (S) $2380

1926.404 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 1, 2013
Abate by
Mar 7, 2013
Penalty
Initial $2,100 · Current $2,100
29 CFR 1926.404(b)(1)(ii):     On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:    a. Parking Area in Front Office Trailer: An employee using the Hitachi circular saw to cut wood shims was plugged into the duplex receptacle in the office trailer and there was no ground fault circuit interrupter protection as determined on 1-29-13.
Recent events (1)
  • — Z (S) $2100

1926.405 A02 II I

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I):     Flexible cords and cables used for temporary wiring were not protected from damage:    a. Parking Area in Front Office Trailer: The red / black extension cord which provide energy to the Hitachi circular saw was exposed to damage due to vehicles had run over it while it was laying in the parking lot as observed on 1-29-13.
Recent events (1)
  • — Z (S) $0

1926.451 C02

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 1, 2013
Abate by
Mar 7, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    a. Corridor 200: There was a section of fabricated frame scaffold which was approximately 5 feet wide and 14 feet long by 9 feet 7.5 inches tall which had 5 of the 6 post setting on top of the base plate in lieu of the base plates being inserted in the post / legs of the scaffold and one leg was not equipped with any base plate as observed on 1-29-13.    ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (1)
  • — Z (S) $2800

1926.451 F03

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 1, 2013
Abate by
Mar 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3):     Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:      a. Corridor 200: There was a section of fabricated frame scaffold which was approximately 5 feet wide and 14 feet long by 9 feet 7.5 inches tall which had 5 of the 6 post setting on top of the base plate in lieu of the base plates being inserted in the post / legs of the scaffold and one leg was not equipped with any base plate. The fabricated framed scaffold was not inspected by a compentent person before employees went to work as determined on 1-29-13.    ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 1, 2013
Penalty
Initial $2,100 · Current $2,100
29 CFR 1926.451(e)(1):     When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    a.Corridor 200: Employees were using the cross bracing to gain access to the top level of the fabricated frame scaffold which was 9 feet 7.5 inches off the ground as observed on 1-29-13.
Recent events (1)
  • — Z (S) $2100

1904.32 B03

Other-than-serious 1 instance 5 exposed
Issued
Mar 1, 2013
Penalty
Initial $595 · Current $595
29 CFR 1904.32(b)(3):      A company executive must certify that he or she has examined the OSHA 300 Log and that he or she reasonably believes, based on his or her knowledge of the process by which the information was recorded, that the annual summary is correct and complete.    a. 2012 OSHA Form 300A:  The 2012 OSHA Form 300A summary of work related injuries and illness was not certified by the highest ranking company executive at the facility.  The facility's Accountant, not a company executive signed the summary, as determined on February 13, 2013.
Recent events (1)
  • — Z (O) $595

View Radford & Radford INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338550437.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.