Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FABCO-AIR, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of FABCO-AIR, INC. in 3716 N.E. 49TH AVE., GAINESVILLE, FL 32609 (NAICS 332911). OSHA activity number 338580434.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fabco-Air, INC. — free Get an email when a new federal OSHA severe-injury report for Fabco-Air, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FABCO-AIR, INC.
Site address
3716 N.E. 49TH AVE.
City
GAINESVILLE
State
FL
ZIP
32609
Mailing
3716 N.E. 49TH. AVE., GAINESVILLE, FL 32609
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332911
Employees
70
Ownership type
A

10 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 2 instances 31 exposed
Issued
Jun 17, 2013
Abate by
Oct 1, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative  a. On or about January 30, 2013, the employer did not have an adequate lockout tagout program in that they did not have written specific procedures, training for authorized and affected employees, and periodic reviews of the program for employees performing service on equipment such as the Biglia and Hwacheon lathe machines.
Recent events (1)
  • — Z (S) $4900

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 17, 2013
Abate by
Aug 2, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a. On or about January 30, 2013, at the job shop area, the McLean manual speed lathe did not have a guard to protect employees from rotating parts.
Recent events (1)
  • — Z (S) $4900

1910.1025 H01

Serious Gravity 10 4 instances 53 exposed
Issued
Jun 17, 2013
Abate by
Aug 2, 2013
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:  a. On or about January 30, 2013, at the CNC production area, the surfaces of the machines, tool boxes, and restrooms were not kept free of accumulations of lead.
Recent events (1)
  • — Z (S) $4900

1910.1025 L01 I

Serious Gravity 10 4 instances 4 exposed
Issued
Jun 17, 2013
Abate by
Aug 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025:  a. On or about January 30, 2013, at the CNC production area, employees manufacturing parts with lead alloy metal rods were not informed about the content of Appendices A and B of the 29 CFR 1910.1025.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 3 instances 67 exposed
Issued
Jun 17, 2013
Abate by
Aug 2, 2013
Penalty
Initial $4,200 · Current $4,200
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   a. On or about January 30, 2013, the employer did not implement or maintain a hazard communication program for employees using chemicals such as but not limited to acetone, oils, lubricants, coolant, and propane.
Recent events (1)
  • — Z (S) $4200

1910.1200 H01

Serious Gravity 5 3 instances 67 exposed
Issued
Jun 17, 2013
Abate by
Aug 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a. On or about January 30, 2013, the employer did not provide training for employees using chemicals such as but not limited to acetone, oils, lubricants, coolant, and propane.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Other-than-serious 1 instance 8 exposed
Issued
Jun 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a. On or about January, 30, 2013, at the northeast corner of the Special Products area, three 240 V electrical panels, identified as P-4, AC-4, and Bussduct-1, did not comply with the minimum working space required to permit ready and safe operation and maintenance of such equipment, in that the working space was about 14 to 20 inches.
Recent events (1)
  • — Z (O) $0

1910.1025 D02

Other-than-serious 1 instance 4 exposed
Issued
Jun 17, 2013
Abate by
Apr 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level:  a. On or about January 30, 2013, at the CNC production area, employees working with lead did not receive an initial assessment to determine if they were exposed to lead at or the action level.
Recent events (1)
  • — Z (O) $0

1910.1200 F05 I

Other-than-serious 2 instances 10 exposed
Issued
Jun 17, 2013
Abate by
Aug 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  a. On or about January 30, 2013, in the Stock Room, containers of Hysol MB 50 coolant were not labeled, tagged or marked with the identity of the chemical.  b.  On or about January 30, 2013, in the Special prducts area, containers of oils and cleaners were not labeled, tagged or marked with the correct identity name.
Recent events (1)
  • — Z (O) $0

1910.1200 F05 II

Other-than-serious 2 instances 10 exposed
Issued
Jun 17, 2013
Abate by
Aug 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  a.  On or about January 30, 2013, in the Stock Room, containers of Hysol MB 50 coolant were not labeled tagged or marked with the appropriate hazard warnings of the chemical.  b.  On or about January 30, 2013, in the Special Products area, containers of oils and cleaners were not labeled, tagged or marked with the appropriate hazard warnings of the chemicals.
Recent events (1)
  • — Z (O) $0

View Fabco-Air, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338580434.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.