Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FABCO AIR, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FABCO AIR, INC. in 3716 E 49TH AVE., GAINESVILLE, FL 32609 (NAICS 332919). OSHA activity number 341009868.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fabco AIR, INC. — free Get an email when a new federal OSHA severe-injury report for Fabco AIR, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FABCO AIR, INC.
Site address
3716 E 49TH AVE.
City
GAINESVILLE
State
FL
ZIP
32609
Mailing
3716 E 49TH AVE., GAINESVILLE, FL 32609
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332919
Employees
80
Ownership type
A

2 citations on file for this inspection.

1910.242 B

Serious Gravity 5 1 instance 18 exposed
Issued
Dec 14, 2015
Abate by
Jan 11, 2016
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a.  On or about October 22, 2015, throughout the shop area, employees used compressed air that blew approximately 100 p.s.i. to remove metal debris from product in the various machines.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Dec 14, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  a.  On or about October 25, 2013, the employer had not conducted annual or more frequent inspections of the energy control procedures.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Fabco AIR, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341009868.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.