REED POINT, MT —
OSHA Inspection: DGO, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DGO, INC in 42 SAWMILL ROAD, REED POINT, MT 59069 (NAICS 321113). OSHA activity number 338685076.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DGO, INC
- Site address
- 42 SAWMILL ROAD
- City
- REED POINT
- State
- MT
- ZIP
- 59069
- Mailing
- PO BOX 56, REED POINT, MT 59069
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 7
- Ownership type
- A
Citations
16 citations on file for this inspection.
5(a)(1)
- Issued
- May 28, 2013
- Abate by
- Jun 21, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that they were exposed to fire hazards: a) Wood Chipper Area; On or about February 4, 2013 and at times prior, employees were exposed to fire hazards while feeding scrap wood into the hog wood chipper with the PVC pipe discharge.
Recent events (3)
- — F (S) $0
- — C (S) $2000
- — Z (S) $2000
1910.22 A01
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition: a) Head Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to slip, trip and fall hazards from walkways that were obstructed with debris such as, but not limited to stacks of lumber and piles of wood debris. b) Trim Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to slip, trip and fall hazards from walkways that were obstructed with debris such as, but not limited to stacks of lumber and piles of wood debris.
Recent events (3)
- — F (S) $1200
- — C (S) $2400
- — Z (S) $2400
1910.147 C01
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment was not isolated from the energy source and rendered inoperative: a) Head Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to unexpected energization during operations such as but not limited to, clearing lumber from the separating conveyor. b) Cut Off Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to unexpected energization during maintenance operations such as but not limited to, sharpening saw blade. c) Trim Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to unexpected energization during maintenance operations such as but not limited to, replacing saw blades or clearing jammed lumber from the saw.
Recent events (3)
- — F (S) $1000
- — C (S) $2000
- — Z (S) $2000
1910.212 A01
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Cut Off Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards while operating an unguarded 30 inch Cut Off Saw.
Recent events (3)
- — F (S) $1400
- — C (S) $2800
- — Z (S) $2800
1910.219 B01
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv): a) Wood Chipper Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation and caught in hazards due to the unguarded flywheel on the hog wood chipper. The flywheel was approximately 28 inches in diameter and approximately 6 inches wide. Bolt and nut fasteners projected through the flywheel approximately 11 inches from the outer edge of the rim.
Recent events (3)
- — F (S) $1400
- — C (S) $2800
- — Z (S) $2800
1910.219 C02 I
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, was not protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires: a) Wood Chipper Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards due to the unguarded bearing supported shaft on the hog wood chipper. The rotating shaft, approximately 2 1/2 inches in diameter, was unguarded approximately 4 inches on both sides of the bearing support.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 C04 I
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Projecting shaft ends did not present a smooth edge and end and projected more than one-half the diameter of the shaft: a) Hog Wood Chipper Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards due to the unguarded protruding shaft on equipment such as but not limited to, the hog wood chipper. The rotating shaft was approximately 9 1/2 inches long and 2 1/2 inches in diameter.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 C04 II
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: a) Hog Wood Chipper Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards due to the unguarded protruding shaft on equipment such as but not limited to, the hog wood chipper. The rotating shaft, approximately 9 1/2 inches long and 2 1/2 inches in diameter, had an unused keyway.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o) this section: a) Yard Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards due to unguarded belt and pulley on the air compressor. b) Trim Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards due to an unguarded belt and pulley on equipment such as but not limited to the trim saw. c) Hog Wood Chipper Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards due to the inadequately guarded belt and pulley on the hog chipper. d) Hog Wood Chipper Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards due to the unguarded belt and pulley on the vibrator motor near the hog chipper.
Recent events (3)
- — F (S) $1400
- — C (S) $2800
- — Z (S) $2800
1910.219 E01 I
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a) Yard Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards from an ingoing nip point from equipment such as but not limited to, the unguarded belt and pulley on the air compressor. b) Trim Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards from an ingoing nip point from an unguarded belt and pulley on equipment such as but not limited to, the trim saw. c) Hog Wood Chipper Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards from an ingoing nip point due to the inadequately guarded belt and pulley on the hog chipper. d) Hog Wood Chipper Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards from an ingoing nip point on an unguarded belt and pulley on equipment such as but not limited to, the electric vibrator motor near the hog wood chipper.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.265 C05 II
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.265(c)(5)(ii): Stairways were not provided with a standard handrail on at least one side or on any open side: a) Head Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to a fall hazard while using stairs to access/egress the main conveyor belt.
Recent events (3)
- — F (S) $600
- — C (S) $1200
- — Z (S) $1200
1910.265 C18 I
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.265(c)(18)(i): Construction, operation, and maintenance of conveyors were not in accordance with American National Standard B20.1-1957, which is incorporated by reference as specified in Sec. 1910.6: a) Trim Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards while walking in and around unguarded sprockets and chains on the conveyors near the trimmer saw deck. b) Head Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards while walking in and around unguarded sprockets and chains on the sorting conveyor. c) Head Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to amputation hazards while walking in and around unguarded sprockets and chains on the log feed.
Recent events (3)
- — F (S) $1400
- — C (S) $2800
- — Z (S) $2800
1910.132 A
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.132(a): Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. a) Sawmill; On or about February 4, 2013 and at times prior, employees were exposed to lacerations to the legs while operating a chainsaw to trim board ends.
Recent events (3)
- — F (S) $1000
- — C (S) $2000
- — Z (S) $2000
1910.303 B07 I
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) Hog Wood Chipper Area: On or about February 4, 2013 and at times prior, employees were exposed to electric shock and/or fire hazards from the open junction box with exposed conductors on the electric motor of the Hog Wood Chipper. b) Trim Saw Area: On or about February 4, 2013 and at times prior, employees were exposed to electric shock and/or fire hazards from the open junction box with exposed conductors on the electric motor near the Trim Saw.
Recent events (3)
- — F (S) $1000
- — C (S) $2000
- — Z (S) $2000
1910.305 G01 IV A
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible extension cords were being used as a substitute for the fixed wiring of a structure: a) Sawmill: On or about February 4, 2013 and at times prior, employees were exposed to electric shock hazards while flexible extension cords were wrapped around ceiling support beams and ran along ceiling joists to provide power to equipment and lights.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- May 28, 2013
- Abate by
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: a) Notching Machine Area: On or about February 4, 2013 and at times prior, employees were exposed to a shock and/or fire hazards from an electrical switch box near the notching machine that did not have strain relief.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at DGO, INC
View DGO, INC's full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in MT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338685076.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.