Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TECNOFIL CHENANGO SAC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TECNOFIL CHENANGO SAC in 40 SOUTH MAIN STREET, SHERBURNE, NY 13460 (NAICS 331421). OSHA activity number 338814635.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tecnofil Chenango SAC — free Get an email when a new federal OSHA severe-injury report for Tecnofil Chenango SAC is published. One employer, no account, unsubscribe in one click.
Site address
40 SOUTH MAIN STREET
City
SHERBURNE
State
NY
ZIP
13460
Mailing
40 SOUTH MAIN STREET, SHERBURNE, NY 13460
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331421
Employees
18
Ownership type
A

30 citations on file for this inspection.

1903.19 C01

Deleted Other-than-serious 1 instance 1 exposed
Issued
Sep 24, 2013
Abate by
Oct 11, 2013
Penalty
Initial $400 · Current $0 Reduced
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  a) At the facility, on or about 9/24/2013:  The employer did not provide abatement certification for Citation 1, Items 1, 5a, 5b, 6c, 13, 17b and 18 issued on June 24, 2013.  An abatement demand letter was sent to the employer on August 30, 2013.  Abatement documentation is required for this item.
Recent events (3)
  • — J (O) $0
  • — C (O) $400
  • — Z (O) $400

5(a)(1)

Serious Gravity 10 4 instances 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,800 · Current $1,960 Reduced
Section (5)(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of being struck by molten copper, steam and shrapnel.       On or about 2/2/2013, Outcast Area:  "Cooler" cylinders used for the drawing of copper wire were not provided with a means to release pressure such pressure relief valves.         Among other methods, a feasible abatement method to correct this hazard is to:            1) Select and include in construction only components that have a working rating equal to or greater than required to meet the maximum recommended conditions as referenced in Section 4.1.2 of ASTM E2349-12, Standard Practice for Safety Requirements in Metal Casting Operations, 2012.         2) Insure that any modifications or alterations to a piece of equipment or machinery which result in a change from the manufacturers original design and/ or intended method of operation shall be done under the supervision of a qualified engineer and shall comply with mandatory safety standards for that given category as referenced in Section 4.1.6 of ASTM E2349-12, Standard Practice for Safety Requirements in Metal Casting Operations, 2012.              3) Insure that any fluids (gas or liquid) are exhausted to locations that will not create a hazardous condition as referenced in Section 4.8 of ASTM E2349-12, Standard Practice for Safety Requirements in Metal Casting Operations, 2012.          4) Insure that if any modifications to equipment is performed, that the modifications have functional engineering drawings as is referenced in Section 5.1.2 of ASTM E2349-12, Standard Practice for Safety Requirements in Metal Casting Operations, 2012.               5) Reinstall, test  and maintain pressure relief valves that had been removed from the cooler cylinders.     Abatement documentation is required for this item.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
Section (5)(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the load should the below-the-hook lifting devices fail:     a) On or about 2/11/2013, Throughout the facility:  Various below the hook lifting devices including, but not limited to drum lifters, annealing bell frames, and hooks were not inspected and did not have load capacity markings:        Among other methods, feasible and acceptable abatement methods to correct these hazards are to:          1) Inspect the lifting devices in accordance with ANSI B30.20-2010, Section 20-1.3         2) Mark the rated load capacity on the device in accordance with ANSI B30-20-2010, Section 10-1.2.     Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.22 A01

Serious Gravity 5 3 instances 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.     a) On or about 2/11/2013, Casting Area:  The deck around the molten copper casting tub was uneven.     b) On or about 2/11/2013, Casting Area:  The stairs leading to the casting pit had pipes running through the steps.      c) On or about 2/11/2013, Furnace Area:  Pipes were running along the top of the steps to the furnace pit.         Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.23 A08 II

Serious Gravity 5 2 instances 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.23(a)(8)(ii): Every floor hole into which persons could accidentally walk was not guarded by a floor hole cover of standard strength and construction:     a) On or about 2/11/2013, Casting Area:  Floor holes located next to the casting tub were not provided with covers.           Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.23 C01

Serious Gravity 10 14 instances 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.     a) On or about 2/11/2013, Casting Area:   A section of the walking surface to the NE of the casting pit had inadequate fall protection as there was no midrail and a chain top rail with approximately 12 inches of deflection.  Employees exposed to falls of over eight feet.       b) On or about 2/11/2013, Casting Platform:  An eighteen inch wide section of the platform was not provided with any fall protection.  Employees were exposed to falls of 7.75 feet.      c) On or about 2/11/2013, Casting Platform:  A three foot by six foot opening in the center of the elevated platform was not provided with any midrails or toeboards.  Employees exposed to falls of 7.75 feet.       d) On or about 2/11/2013,  South East section of the Casting Platform:  No midrails were provided for over twenty feet of platform edge.  A chain top rail had over ten inches of deflection. Employees exposed to falls of 7.75 feet.     e) On or about 2/11/2013, South West section of the Casting Platform:  A series of top rails and midrails had over twenty inches of deflection.  Employees exposed to falls of 7.75 feet.       f) On or about 2/11/2013, On top of the Caster/ Furnace:  A platform on top of the Caster/ Furnace was not provided with any fall protection.  Employees exposed to falls of fifteen feet.       g) On or about 2/11/2013, At the South corner of the Caster/ Furnace:  An access platform was not provided with fall protection.  Employees were exposed to falls of nine feet.       h) On or about 2/11/2013, At the South corner of the Caster/ Furnace:  A section of open sided plant floor at the slag removal area was not provided with fall protection.  Employees exposed to falls of approximately eight feet.     i) On or about 2/11/2013, Maintenance Shop:  A storage platform was not provided with fall protection.  Employees exposed to falls of nine and a half feet.     j) On or about 2/15/2013, In the Facility:  A Holland High Lift was not equipped with midrails in two locations.  Employees exposed to falls of over six feet.     k) On or about 2/15/2013, C13 Machine Power Platform:  The C13 power platform was not provided with a guardrail system.  Employees are exposed to falls of over seven feet.     l) On or about 2/15/2013, North East end of the Furnace Pit:  A section of guardrail was only supported by a center post, allowing for the sections on either side of the center post to pivot.  Employees were exposed to falls of eight feet.     m) On or about 2/15/2013, North East side of the Outokumph Furnace:  An eighteen inch section of guardrail system was missing.  Employees exposed to falls of nine feet.     n) On or about 2/15/2013, North East side of the Outokumph Furnace:  A top rail was at a height of thirty two inches and a mid rail at a height of eight inches above a small platform.  Employees exposed to falls of over nine feet.       Abatement documentation is required for these items.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.23 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board.   a) On or about 2/15/2013, Furnace:  A platform on top of the furnace, located above the four foot by two foot furnace opening was not provided with rails or other forms of fall prevention to protect employees while adding bags of charcoal.  Employees exposed to falls into the furnace and molten copper.      Abatement documentation is required for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 D01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.23(d)(1)(i): Flight(s) of stairs with four or more risers, less than 44 inches wide and having both sides enclosed, were not equipped with at least one standard handrail:     a) On or about 2/11/2013, Lab Area:  A set of stairs from the Lab Area leading to the Sample Room were not provided with a standard handrail.           Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.23 D01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(d)(1)(ii): Stairway(s) less than 44 inches wide having one side open, did not have at least one stair railing on the open side:   a) On or about 2/11/2013, Casting Area:  A set of stairs leading to the casting pit was not provided with a stair rail on the open side.         Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.24 E

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.24(e): Fixed stairs were not installed at angles to the horizontal of between 30 degrees and 50 degrees:   a) On or about 2/11/2013, Casting Area:  A set of stairs leading to the casting pit was installed at an angle of approximately 61 degrees to the horizon.          Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.36 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:     a) On or about 2/11/2013, Annealing Area:  A marked exit door was not able to be opened.         Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.37 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:     a) On or about 2/11/2013, Casting Area:  Existing emergency lighting was not operable.      Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     a) On or about 2/11/2013, Throughout the facility:  Employees engaged in maintenance and production activities were not provided with or utilizing lock out procedures while working on machines such as, but not limited to the Furnace, Caster, and Draw Machines.             Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   a) On or about 2/11/2013, Throughout the facility:  There was no periodic review of the companies lock out program to ensure that procedures and requirements of the standard were being followed.     Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:     a) On or about 2/11/2013, Throughout the facility:  Employees engaged in maintenance and production activities were not provided adequate locking devices, while working on machines such as, but not limited to the Furnace, Caster, and Draw Machines.              Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  a) On or about 2/11/2013, Throughout the facility:  Employees engaged in maintenance and production activities were not provided adequate lock out tag out training.              Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.169 B03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.169(b)(3)(i): Compressed air receiver(s) were not equipped with one or more spring-loaded safety valves:     a) On or about 2/11/2013, Near Offices:  A seventeen inch diameter by three foot tall air receiver (pressure vessel) was not provided with any pressure relief valve.         Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):     a) On or about 2/15/2013, Throughout the facility:  Employees operating a powered industrial truck were not provided with training.          Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.212 A01

Serious Gravity 10 8 instances 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     a) On or about 2/11/2013, Laboratory:  No guarding or operable emergency stop was provided for the Gold Machinery Roller.          b) On or about 2/11/2013, Die Room:  No guarding was provided for the rotating spoked wheel of the Sauk Engineering Lathe, Model MD-2.     c) On or about 2/11/2013, Draw Machine Area:  The Vauhn Bull Block Draw Machine was operated with its cover/ door open and interlock bypassed.     d) On or about 2/15/2013, Draw Machine Area:  The Vaughn Bull Block Draw Machine and associated wire pulleys were being operated without guarding.     e) On or about 2/15/2013, Draw Machine Area:  The Three Die Draw Machine was being operated without guards being in place, with interlocks bypassed and safety cables in operable.      f) On or about 2/15/2013, Draw Machine Area:  The UDM 22 Draw Machine is operated without a guard in place and with the interlock bypassed.      g) On or about 2/15/2013, Draw Machine Area:  The rotating "pay off" at the UDM 22 Draw Machine was not secured to prevent movement.     h) On or about 2/15/2013, Draw Machine Area:  The rotating "pay off" at the UDM 22 Draw Machine did not have its rotating parts guarded.       Abatement documentation is required for this item.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:     a) On or about 2/15/2013,  Maintenance Area:  A bench grinder was in use with a work rest over one inch away from the wheel.           Abatement certification is required for this item.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   a) On or about 2/15/2013,  Maintenance Area:  A bench grinder was in use with a tongue guard that was over one inch away from the wheel.          Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 2 instances 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:     a) On or about 2/11/2013,  Die Area:  A Suak Engineering Lathe, Model MD-2 had two unguarded horizontal shafts.     b) On or about 2/11/2013, Die Area:  A Die Quip Corp Die Finisher had unguarded horizontal shafts.      Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):     a) On or about 2/11/2013,  Die Area:  A Die Quip Corp horizontal die finisher machine had a series of unguarded pulleys.      Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.219 E03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):   a) On or about 2/11/2013,  Die Area:  A Die Quip Corp horizontal die finisher machine had an unguarded belt   Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 6 instances 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:     a) On or about 2/11/2013,  Buhler Area:  A series of electrical boxes were hanging from their power supply cords, not secured.         b) On or about 2/11/2013, Electrical Room:  Water intrusion was observed onto and into a green colored electrical panel next to the North East wall.         c) On or about 2/11/2013, Draw Machine Area:  A power supply cabinet for the Three Die Machine was damaged in that the external power control handle was disabled, and the latching mechanism for the doors was removed.        d) On or about 2/11/2013, Maintenance Department:  A power cord reel had damaged cord ends at both the ends of the power supply cord.       e) On or about 2/15/2013, Draw Machine Area:  The top cover on an August KG Welder was not secured.     f) On or about 2/15/2013, Furnace Power Supply Area:  A junction box North West of the furnace was damaged so that wires were falling out of it.     Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.305 G02 III

Serious Gravity 5 2 instances 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   a) On or about 2/11/2013, Air Compressor Area:  There was no strain relief provided for the power cord of the Sullair 2200 Air Compressor, where the cord exited the power shut off box.    b) On or about 2/11/2013,  Die Maintenance Area:  There was no strain relief on wiring for a limit switch attached to the Die Quip Corp. machine.        Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 10 4 instances 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):     a) On or about 2/11/2013,  Electrical Room:  Two fan control switch boxes had parts missing, exposing energized parts.       b) On or about 2/11/2013, Draw Machine Area:  A power supply cabinet for the Three Die Machine was open, and employees reach inside to control the machine.        c) On or about 2/11/2013, Electric Room:  The doors on floor mounted panel A4 were not closed, exposing energized parts.      d) On or about  2/15/2013, Furnace Area:  One light fixture had a missing cover, one had a damaged cover, exposing energized parts.     Abatement documentation is required for this item.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:      a) On or about 2/15/2013,  Draw Machine Area:  An August KG Welder was not provided with a continuous path to ground.          Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.332 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:     a) On or about 2/11/2013,  Throughout the Facility:  Maintenance workers performing electrical trouble shooting work on machines and equipment along with racking high voltage breakers were not provided with training regarding the selection and use of appropriate Personal Protective Equipment along with the requirements of safety related work practices and NFPA 70E.          Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.333 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.333(a)(2): Where exposed live parts were not deenergized (i.e., for reasons of increased or additional hazards or infeasibility), other safety-related work practices were not used to protect employees who could be exposed to the electrical hazards involved:   a) On or about 2/11/2013,  Throughout the Facility:  Maintenance workers performing electrical trouble shooting work on machines and equipment along with racking high voltage breakers were not utilizing safety related work practices such as, but not limited to proper training and PPE.         Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Tecnofil Chenango SAC's full OSHA safety record →