Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MATTHEW T. KING DBA DURANGO CUSTOM BUILDERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MATTHEW T. KING DBA DURANGO CUSTOM BUILDERS in 2809 BEVERLY LANE, ARLINGTON HEIGHTS, IL 60004 (NAICS 238160). OSHA activity number 338848054.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Matthew T. King DBA Durango Custom Builders — free Get an email when a new federal OSHA severe-injury report for Matthew T. King DBA Durango Custom Builders is published. One employer, no account, unsubscribe in one click.
Site address
2809 BEVERLY LANE
City
ARLINGTON HEIGHTS
State
IL
ZIP
60004
Mailing
1216 SYCAMORE STREET, LAKE IN THE HILLS, IL 60156
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 4 instances 4 exposed
Issued
Feb 27, 2013
Abate by
Mar 5, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b). Note:  If using these systems was infeasible or created a greater hazard, the employer should develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502:    a) Employees were exposed to the hazard of falling from a steep pitched roof having a ground to eave height of approximately 20 feet while performing roofing work without the use of fall protection.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $2800

1926.451 G01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 27, 2013
Abate by
Mar 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(i): Each employee on a boatswain's chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold, was not protected by a personal fall arrest system:    a) Employees were exposed to the hazard of falling approximately 20 feet while working from ladder jack scaffolding without fall protection.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 27, 2013
Abate by
Mar 5, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet above or below the point of access:    a) Employees were exposed to the hazard of falling approximately 20 feet where safe access was not provided to ladder jack scaffolding when the point of access was between a roof eave and the scaffold work platform.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $2800

View Matthew T. King DBA Durango Custom Builders's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338848054.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.