Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COASTAL MARINE ENTERPRISES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COASTAL MARINE ENTERPRISES, INC. in 2079 AUSTIN AVENUE, CHARLESTON, SC 29405 (NAICS 336612). OSHA activity number 338906977.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coastal Marine Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for Coastal Marine Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2079 AUSTIN AVENUE
City
CHARLESTON
State
SC
ZIP
29405
Mailing
2079 AUSTIN AVENUE, CHARLESTON, SC 29405
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
5
Ownership type
A

9 citations on file for this inspection.

1910.178 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 26, 2013
Abate by
May 22, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered:    a) Worksite: A 1940's era Clark forklift had a jib crane permanently attached to the front (This was done decades before the company purchased the forklift), however there were neither markings on the forklift nor any paper work which identified the new attachments and updated lifting and maneuvering capabilities which were affected by these additions.       ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.178 P

Serious Gravity 1 2 instances 9 exposed
Issued
Apr 26, 2013
Abate by
May 22, 2013
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.178(p): A powered industrial truck found to be in need of repair, defective, or anyway unsafe was not taken out of service until it has been restored to a safe operating condition.     a) Worksite: A Clark forklift used at the jobsite was not equipped with a functioning horn.     b) Worksite: A Taylor forklift used at the jobsite was not equipped with a functioning horn.     ABATEMENT CERIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.215 B09

Other-than-serious 1 instance 2 exposed
Issued
Apr 26, 2013
Abate by
May 8, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.    a) East wall of the Small Engine Shop: A Ryobi bench grinder was not equipped with a tongue guard over the right-hand side abrasive wheel. There was a gap of 1/2 inch between the abrasive wheel and the peripheral member.     ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $1600

1910.304 G05

Serious Gravity 5 2 instances 1 exposed
Issued
Apr 26, 2013
Abate by
May 8, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.    a) North wall of the Small Engine Shop: The power cord for the parts washer was missing the ground pin.     b) West wall of the Small Engine Shop: The power cord for the drop light was missing the ground pin.     ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 B01 II

Serious Gravity 5 2 instances 1 exposed
Issued
Apr 26, 2013
Abate by
May 8, 2013
Penalty
Initial $2,000 · Current $800 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a) West wall of the Small Engine Shop: Two duplex receptacle outlets mounted on a metal post one above the other, each had an unused opening 1-inch in diameter which was not closed.     ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

1910.305 G01 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 26, 2013
Abate by
May 8, 2013
Penalty
Initial $2,000 · Current $800 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):    a) North wall of the Small Engine Shop: The 120 volt power cord to the water cooler located outside of the shop, passed through a 1.5 inch in diameter opening in the metal wall where it was plugged into a quad receptacle outlet inside the building.     ABATEMENT CERTIFICATION IS REQURIED.
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

1915.93 B03

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 26, 2013
Abate by
May 22, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1915.93(b)(3):   The employer did not replace safety equipment that was removed from a vehicle.    a) Worksite:  The employer removed the worn-out seat and seatbelt from the Taylor forklift, Model TSE-110-01, SN# S-E4-20699 a year ago, the seat was replaced; but the seat belt was not.     ABATEMENT CERIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 A02 IX

Other-than-serious 8 instances 1 exposed
Issued
Apr 26, 2013
Abate by
May 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard:    a) West wall of the Small Engine Shop: Two sets of fluorescent lights (of four bulbs each) hung over the workbench were not provided with covers or other means to protect the bulbs from damage or breakage.     ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 J02 I

Other-than-serious 1 instance 1 exposed
Issued
Apr 26, 2013
Abate by
May 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(i): All 15- and 20-ampere attachment plugs and connectors shall be constructed so that there are no exposed current-carrying parts except the prongs, blades, or pins:    a) North wall of the Small Engine Shop: The 120 volt power cord to the water cooler was missing the cover to the plug, exposing the wiring found underneath the prongs and pins.    ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Coastal Marine Enterprises, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338906977.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.