Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: H & D PALLETS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of H & D PALLETS, LLC in 464 GARRISON SHOALS ROAD, LULA, GA 30554 (NAICS 321920). OSHA activity number 338913452.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch H & D Pallets, LLC for free Get an email when a new federal OSHA severe-injury report for H & D Pallets, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
H & D PALLETS, LLC
Site address
464 GARRISON SHOALS ROAD
City
LULA
State
GA
ZIP
30554
Mailing
464 GARRISON SHOALS ROAD, LULA, GA 30554
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
21
Ownership type
Private (A)

8 citations on file for this inspection.

1910.157 E02

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 14, 2013
Abate by
Apr 18, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    On or about 2/20/2013 at 464 Garrison Shoals Road Lula, Ga; employees were exposed to smoke inhalation and burn hazards where portable fire extinguishers were not inspected on a monthly basis.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.157 E03

Serious Gravity 10 1 instance 21 exposed
Issued
Mar 14, 2013
Abate by
Apr 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:    On or about 2/20/2013 at 464 Garrison Shoals Road Lula, Ga; employees were exposed to smoke inhalation and burn hazards where the portable fire extinguishers were not inspected on an annual basis. The last annual inspection was conducted on 2/28/2011, 4/4/2008, and 4/11/2005. There was an extinguisher discovered to be discharged.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A05

Serious Gravity 10 1 instance 21 exposed
Issued
Mar 14, 2013
Abate by
Apr 18, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    On or about 2/20/2013 at 464 Garrison Shoals Road Lula, Ga; employees were exposed to potential amputation hazards where an unguarded 36" fan was located 72" above the floor, in a highly traveled area.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.213 A12

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 14, 2013
Abate by
Mar 26, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.213(a)(12): The portion of circular saw(s) beneath or behind the table, where there was a possibility of contact with the saw, was not covered with an adequate guard or exhaust hood:    On or about 02/20/2013 at 464 Garrison Shoals Road Lula, Ga; employees were exposed to amputation hazards where two table saws used on a constant, daily basis were not adequately guarded against employees making contact with the blades.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.242 B

Serious Gravity 5 1 instance 21 exposed
Issued
Mar 14, 2013
Abate by
Mar 26, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    On or about 02/20/2013 at 464 Garrison Shoals Road Lula, Ga; employees were exposed to struck-by hazards where compressed air was used to clean the floors and personnel of wood dust. The PSI measured at the output was 83 and the compresser was set to 120 PSI.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.303 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2013
Abate by
Mar 26, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On or about 2/20/2013 at 464 Garrison Shoals Road Lula, Ga; employees were exposed to 220 V electrical hazards where the electrical panel that is accessed twice a day on a daily basis, to power the electrical saws on and off, did not have a dead front.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.305 G02 III

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 14, 2013
Abate by
Mar 26, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    On or about 2/20/2013 at 464 Garrison Shoals Road Lula, Ga; employees were exposed to electrical hazards where 220V cables pulled were from the electrical box where there was no strain relief devices installed.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.178 L04 III

Other-than-serious 1 instance 21 exposed
Issued
Mar 14, 2013
Abate by
Apr 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    On or about 2/20/2013 at 464 Garrison Shoals Road Lula, Ga; employees operate the powered industrial trucks without being re-evaluated every three years.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View H & D Pallets, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338913452.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.