TALLAHASSEE, FL —
OSHA Inspection: MANUEL FRAMING, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MANUEL FRAMING, LLC. in 2590 MANASSAS WAY, TALLAHASSEE, FL 32312 (NAICS 238130). OSHA activity number 338916075.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANUEL FRAMING, LLC.
- Site address
- 2590 MANASSAS WAY
- City
- TALLAHASSEE
- State
- FL
- ZIP
- 32312
- Mailing
- 260 PRIMROSE LANE #300, QUINCY, FL 32351
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 A
- Issued
- May 22, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1926.403(a): Electrical conductors and equipment were not approved: a. On or about February 22, 2013, framing employees operating electric power tools outdoors were exposed to a 120-Volt electric shock hazard in that the temporary electric receptacle junction box was assembled from components not approved for use for exterior wiring.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1926.403 I02
- Issued
- May 22, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(2): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures: a. On or about February 22, 2013, framing employees operating electric power tools outdoors were exposed to a 120-Volt electric shock hazard in that the temporary electric receptacle junction box had exposed live conductors.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 B01 II
- Issued
- May 22, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a. On or about February 22, 2013, framing employees operating electric power tools and battery chargers outdoors were exposed to a 120-Volt electric shock hazard in that the tools were powered by a circuit that was not protected by a ground fault circuit interrupter.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1926.1053 B01
- Issued
- May 22, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: a. On or about February 22, 2013, the roof access ladder did not extend three feet above the eave, exposing employees to a 10 feet fall hazard.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.501 B13
- Issued
- May 22, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $4,800 · Current $2,880 Reduced
General-duty citation text
Manuel Framing, LLC. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 671901, citation number 001, item number 002 and was affirmed as a final order on November 27, 2012, with respect to a workplace located at 2557 Ulysses Rd, Tallahassee, FL32312. 29 CFR 1926.501(b)(13): 29 CFR 1926.501 (b)(13) Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a. On or about February 22, 2013, framing employees installing cross bracing in the roof trusses were exposed to a 9 feet fall hazard in that they were not protected by a fall protection system.
Recent events (2)
- — I (R) $2880
- — Z (R) $4800
More inspections at Manuel Framing, LLC.
View Manuel Framing, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338916075.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.