On , OSHA opened a planned safety inspection of MANUEL FRAMING, LLC. in 2590 MANASSAS WAY, TALLAHASSEE, FL 32312 (NAICS 238130). OSHA activity number 338916075.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manuel Framing, LLC. — free Get an email when a new federal OSHA severe-injury report for Manuel Framing, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
2590 MANASSAS WAY
City
TALLAHASSEE
State
FL
ZIP
32312
Mailing
260 PRIMROSE LANE #300, QUINCY, FL 32351
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.403 A

Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2013
Abate by
May 22, 2013
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1926.403(a):  Electrical conductors and equipment were not approved:    a.   On or about February 22, 2013, framing employees operating electric power tools outdoors were exposed to a 120-Volt electric shock hazard in that the temporary electric receptacle junction box was assembled from components not approved for use for exterior wiring.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1926.403 I02

Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2013
Abate by
May 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.403(i)(2): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures:  a.   On or about February 22, 2013, framing employees operating electric power tools outdoors were exposed to a 120-Volt electric shock hazard in that the temporary electric receptacle junction box had exposed live conductors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2013
Abate by
May 22, 2013
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1926.404(b)(1)(ii):   On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:    a.   On or about February 22, 2013, framing employees operating electric power tools and battery chargers outdoors were exposed to a 120-Volt electric shock hazard in that the tools were powered by a circuit that was not protected by a ground fault circuit interrupter.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2013
Abate by
May 22, 2013
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.1053(b)(1):  Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access:    a.   On or about February 22, 2013, the roof access ladder did not extend three feet above the eave, exposing employees to a 10 feet fall hazard.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.501 B13

Repeat Gravity 5 1 instance 1 exposed
Issued
May 22, 2013
Abate by
May 22, 2013
Penalty
Initial $4,800 · Current $2,880 Reduced
Manuel Framing, LLC. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 671901, citation number 001, item number 002 and was affirmed as a final order on November 27, 2012, with respect to a workplace located at 2557 Ulysses Rd, Tallahassee, FL32312.    29 CFR 1926.501(b)(13): 29 CFR 1926.501 (b)(13)   Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:    a.  On or about February 22, 2013, framing employees installing cross bracing in the roof trusses were exposed to a 9 feet fall hazard in that they were not protected by a fall protection system.
Recent events (2)
  • — I (R) $2880
  • — Z (R) $4800

View Manuel Framing, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338916075.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.