SPRINGFIELD, MO —
OSHA Inspection: TANK COMPONENTS INDUSTRIES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TANK COMPONENTS INDUSTRIES in 4520 W. KEARNEY ST., STE.100, SPRINGFIELD, MO 65803 (NAICS 332420). OSHA activity number 338947740.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TANK COMPONENTS INDUSTRIES
- Site address
- 4520 W. KEARNEY ST., STE.100
- City
- SPRINGFIELD
- State
- MO
- ZIP
- 65803
- Mailing
- 4520 W. KEARNEY ST., STE.100, SPRINGFIELD, MO 65803
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332420
- Employees
- 52
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.179 J02 III
- Issued
- Apr 5, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $2,625 · Current $1,838 Reduced
General-duty citation text
1910.179(j)(2)(iii): Frequent Inspection: Monthly inspection of overhead crane load hooks, with a certification record which included the date of inspection, the signature of the person who performed the inspection and an identifier of the hook which was inspected, was not performed. (a) On, or at dates prior to, March 6, 2013, production area employees were exposed to a struck by hazard from possible failure of load hooks because monthly inspections for deformities or cracks were not accomplished or documented since June, 2012. Abatement Note: Abatement certification is not required for this item
Recent events (2)
- — I (S) $1837.5
- — Z (S) $2625
1910.179 J02 IV
- Issued
- Apr 5, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $2,625 · Current $1,838 Reduced
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Frequent Inspection: Monthly inspection of overhead crane hoist chains, with a certification record which included the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, was not performed. (a) On, or at dates prior to, March 6, 2013, production area employees were exposed to a struck by hazard from possible failure of hoist chains because monthly inspections for excessive wear, twists, or distorted links were not accomplished or documented since June, 2012. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (S) $1837.5
- — Z (S) $2625
1910.184 E01
- Issued
- Apr 5, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $2,625 · Current $1,838 Reduced
General-duty citation text
29 CFR 1910.184(e)(1) Sling Identification: Alloy steel chains did not have permanently affixed durable identification stating size, grade, rated capacity, and reach. (a) On, or at dates prior to, March 6, 2013, employees were exposed to a struck by hazard because hoist chains had no identification to indicate their capability or maximum lifting capacity. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (S) $1837.5
- — Z (S) $2625
1910.303 G01
- Issued
- Apr 5, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.303(g)(1) Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. (a) On, or at dates prior to, March 6, 2013, production area employees were exposed to hazard from failure to provide and maintain adequate working space in front of electrical equipment including a Square D switch box supplying power to overhead crane 3 which was blocked by a scrap bid. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.305 G01 IV A
- Issued
- Apr 5, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $1,575 · Current $1,103 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A) Flexible cords and cables may not be used as a substitute for the fixed wiring of a structure: a) On, or at dates prior to, March 6, 2013, production area employees were exposed to a fire hazard due to the improper use of flexible electrical cord as permanent fixed wiring of electrical equipment. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (S) $1102.5
- — Z (S) $1575
More inspections at Tank Components Industries
View Tank Components Industries's full OSHA safety record →
More inspections in this industry (NAICS 332420)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338947740.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.