NORTH KANSAS CITY, MO ·
OSHA Inspection: HD SUPPLY CONSTRUCTION SUPPLY, LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HD SUPPLY CONSTRUCTION SUPPLY, LTD. in 1907 WARREN STREET, NORTH KANSAS CITY, MO 64116 (NAICS 423390). OSHA activity number 338961048.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HD SUPPLY CONSTRUCTION SUPPLY, LTD.
- Site address
- 1907 WARREN STREET
- City
- NORTH KANSAS CITY
- State
- MO
- ZIP
- 64116
- Mailing
- 1907 WARREN STREET, NORTH KANSAS CITY, MO 64116
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423390
- Employees
- 15
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.303 G01 II
- Issued
- Mar 27, 2013
- Penalty
- Initial $2,550 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Tool Hospital/Repair: There were 3 dehumidifiers stored in front of the electrical panel. (b) Front Warehouse: An ice melt spreader, two buckets, and other materials were stored in front of the electrical panel.
Recent events (2)
- · I (O) $1000
- · Z (S) $2550
1910.305 G01 IV C
- Issued
- Mar 27, 2013
- Penalty
- Initial $2,550 · Current $500 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were used where run through doorways, windows, or similar openings. (a) Shipping/Receiving: An electrical cord was run under a closed overhead door from Tool Hospital/Repair to Shipping/Receiving to power a radio subjecting the electrical cord to abrasion.
Recent events (2)
- · I (O) $500
- · Z (S) $2550
1910.305 G01 IV D
- Issued
- Mar 27, 2013
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces: (a) Tool Hospital/Repair: There was a relocatable power tap device attached to the wall.
Recent events (2)
- · I (S) $0
- · Z (S) $2550
1910.303 B01 IV
- Issued
- Mar 27, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $2,550 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical conductors: (a) South Warehouse: The Workhorse Series 2 battery charger cable was defective, in that the outer electrical insulation has pulled away from the connector plug housing exposing the live electrical conductors. (b) Tolol Hospital/Repair: The Workhorse Series 2 battery charger cable and connector plug had been repaired with electrical tape.
Recent events (2)
- · I (S) $1785
- · Z (S) $2550
More inspections at HD Supply Construction Supply, LTD.
View HD Supply Construction Supply, LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 423390)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338961048.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.