OSHA Inspection: AMERICAN MADE TIRES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN MADE TIRES in 1717 GRAND CENTRAL AVENUE, ELMIRA HEIGHTS, NY 14903 (NAICS 326212). OSHA activity number 338964943.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Made Tires — free Get an email when a new federal OSHA severe-injury report for American Made Tires is published. One employer, no account, unsubscribe in one click.
Establishment
AMERICAN MADE TIRES
Site address
1717 GRAND CENTRAL AVENUE
City
ELMIRA HEIGHTS
State
NY
ZIP
14903
Mailing
1717 GRAND CENTRAL AVENUE, ELMIRA HEIGHTS, NY 14903
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326212
Employees
6
Ownership type
A

31 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.   a) On or about 3/25/2013, Tire Buffing Area:  Housekeeping to remove and control the amount of combustible rubber dust was not performed on a routine basis.     Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.23 D01 IV

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1910.23(d)(1)(iv): Stairways more than 44 inches wide but less than 88 inches wide, did not have a stair railing on each open side:   a) On or about 3/25/2013, Shipping Dock Area:  Exterior exit stairs were not equipped with a handrail.   Abatement certification is required for this item.
Recent events (5)
  • — J $18000
  • — C $18000
  • — Z $18000

1910.36 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.36(d)(1): Exit doors were locked and/ or employees were not able to open an exit route door from the inside at all times without keys, tools or special knowledge:   a) On or about 3/25/2013, Shipping Dock Area:  A marked exit door had a slide latch engaged along with a panic bar.    b) On or about 3/25/2013, Tread Machine Area:  A marked exit door had a slide latch engaged along with a panic bar.   Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.37 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":   a) On or about 3/25/2013, Front Tire Storage Area:  Two exit doors were not provided with "exit" signs.     Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E02 IV A

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.106(e)(2)(iv)(a): Flammable liquids were not kept in covered containers when not in use:   a) On or about 3/25/2013, Tire Buffer Area:  Metal storage containers, containing flammable adhesive had uncovered openings in their tops.                 Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.107 E02

Serious 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift.    a) On or about 3/25/2013, Tire Buffer Area:  A spray booth being used to spray flammable adhesive had more flammable liquid present in storage than would be required for a one day supply.           Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E05 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.106(e)(5)(i): Portable fire extinguishment and control equipment was not provided in such quantities and types as were needed for special hazards of operation and storage:   a) On or about 3/25/2013, Tire Buffing Area:  Flammable liquid adhesive storage area was not provided with an operable fire extinguisher.      Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.157 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   a) On or about 3/25/2013, Tire Buffing Area:  A portable fire extinguisher was blocked by a large wooden structure, boxes and duct work.   Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C04

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:     a) On or about 3/25/2013, Tire Buffing Area:  Two portable fire extinguishers were not fully charged per their gauges.   b) On or about 3/25/2013, Main Tire Storage Area:  One portable fire extinguisher was not fully discharged per its gauge.   c) On or about 3/25/2013, Work Bench Area:  Four portable fire extinguishers were not fully charged per their gauges.   Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.107(b)(1): The spray booth was not substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying:   a) On or about 3/25/2013, Tire Buffer Area:  A spray booth being used to spray flammable adhesive was partially constructed with wood.      Abatement certification is required for this item.
Recent events (5)
  • — J $24000
  • — C $24000
  • — Z $24000

1910.107 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(2): The interior surfaces of spray booths were not smooth and continuous without edges and otherwise designed to prevent pocketing of residues and facilitate cleaning and washing without injury:   a) On or about 3/25/2013, Tire Buffer Area:  A spray booth being used to spray flammable adhesive had multiple edges, surfaces, and void spaces with debris, which allowed for over spray residue.    Abatement certification is required for this item.
Recent events (5)
  • — J $0
  • — C $0
  • — Z $0

1910.107 B06

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(6): Spray booth(s) having a frontal area larger than 9 square feet did not have metal deflectors or curtains not less than 2 1/2 inches deep installed at the upper outer edge of the booth over the opening:   a) On or about 3/25/2013, Tire Buffer Area:  A spray booth being used to spray flammable adhesive was not provided with a deflector at the upper edge of the spray booth.      Abatement certification is required for this item.
Recent events (5)
  • — J $0
  • — C $0
  • — Z $0

1910.107 B08

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(8): Each spray booths was not separated from other operations by not less than 3 feet, or by a greater distance, or by such partition or wall as to reduce the danger from juxtaposition of hazardous operations:   a) On or about 3/25/2013, Tire Buffer Area:  A spray booth being used to spray flammable adhesive was not separated from other operations by at least three feet on all sides of the booth.         Abatement certification is required for this item.
Recent events (5)
  • — J $0
  • — C $0
  • — Z $0

1910.107 B09

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9): Spray booths were not so installed that all portions are readily accessible for cleaning:   a) On or about 3/25/2013, Tire Buffer Area:  A spray booth being used to spray flammable adhesive had void spaces in the rear of the booth and had limited access on the back side of the booth.    Abatement certification is required for this item.
Recent events (5)
  • — J $0
  • — C $0
  • — Z $0

1910.107 C02

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.107(c)(2): Open flame or spark producing equipment was not kept from a spraying area nor within 20 feet, unless separated from by a partition:   a) On or about 3/25/2013, Tire Buffer Area:  A spray booth being used to spray flammable adhesive was located less than twenty feet from the buffing operation and open electrical control cabinet.         Abatement certification is required for this item.
Recent events (5)
  • — J $24000
  • — C $24000
  • — Z $24000

1910.107 D02

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(d)(2): All spraying areas were not provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life is not endangered:    a) On or about 3/25/2013, Tire Buffer Area:  A spray booth being used to spray flammable adhesive was not provided with any mechanical ventilation.            Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   a) On or about 3/25/2013, Throughout the Facility:  Lock Out procedures were not developed, documented nor utilized while employees were performing set up and maintenance work on equipment such as, but not limited to a Tire Buffer, Tire Presses, and Tread Machine.  The equipment was energized with multiple energy sources such as electrical, pneumatic and steam.       Abatement certification is required for this item.
Recent events (5)
  • — J $30000
  • — C $30000
  • — Z $30000

1910.147 C05 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:   a) On or about 3/25/2013, Throughout the Facility:  No hardware to facilitate the locking out of machines and equipment was provided.        Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:   a) On or about 3/25/2013, Throughout the Facility:  No training was provided in order to educate workers on the purpose and use of a lock out program.     Abatement certification is required for this item.
Recent events (5)
  • — J $0
  • — C $0
  • — Z $0

1910.176 B

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:   a) On or about 3/25/2013, Main Tire Storage Area:  Columns of tires were stacked and unstable, leaning into travel paths.        Abatement certification is required for this item.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):   a) On or about 3/25/2013, Throughout the Facility:  Employees operating a powered industrial truck were not provided with training.         Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.212 A01

Serious Gravity 5 3 instances 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a) On or about 3/25/2013, Tire Inspection Area:  The rotating tire inspection machine was not provided with a guard or constant pressure switch.   b) On or about 3/25/2013, Tire Buffing Area:  The tire buffer was not provided with a guard for the rotating tire, tire support and buffer head.   c) On or about 3/25/2013, Tire Press Area:  The tire presses were not provided with guards, employees exposed to moving arms and matrix.     Abatement certification is required for these items.
Recent events (5)
  • — J $30000
  • — C $30000
  • — Z $30000

1910.219 F03

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:   a) On or about 3/25/2013, Tire Inspection Area:   The "Cincinnati Systems" tire inspection machine had an unguarded sprocket and chain.    Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.242 B

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:   a) On or about 3/25/2013, Tire Buffer Area:  Compressed air used for cleaning was at a pressure of over 100 p.s.i., without any reduction method in use.    Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.303 B01

Serious Gravity 5 3 instances 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:   a) On or about 3/25/2013, Shipping Dock Area:  An electrical outlet box was damaged.   b) On or about 3/25/2013, Tread Area:  A foot pedal was damaged.   c) On or about 3/25/2013, Tread Area:  Wall mounted wire mold was damaged.    Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.303 G02 I

Serious Gravity 5 7 instances 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):   a) On or about 3/25/2013, Shipping Dock Area:  An electrical outlet box had exposed, energized parts and wire.    b) On or about 3/25/2013, Tire Buffing Area:  The control cabinet for the buffing machine was open, exposing energized parts.   c) On or about 3/25/2013, Tire Press Area:  CIMA tire press machines had control cabinets that were open, exposing energized parts.   d) On or about 3/25/2013, Tire Press Area:  CIMA tire press machines had energized, bare wires outside of any cabinets or boxes.   e) On or about 3/25/2013, Boiler Area:  The Fulton boiler had an open control box, exposing energized parts.   f) On or about 3/25/2013, Tread Area:  The control cabinet for the Side Wall Machine was open, exposing energized parts.   g) On or about 3/25/2013, Tread Area:  The rear electrical cabinet on the Tread Machine did not have its door in place, exposing energized parts.     Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 A02

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity:   a) On or about 3/25/2013, Tire Inspection Area:  A metal framed window fan was energized through a circuit that had its polarity reversed.        Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.304 G05

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   a) On or about 3/25/2013, Tire Inspection Area:  A metal framed window fan was not provided with a continuous path to ground.    b) On or about 3/25/2013, Tire Inspection Area:  The metal Cincinnati Systems inspection machine was not provided with a continuous path to ground.   Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   a) On or about 3/25/2013, Throughout the facility:  Workers were using and exposed to items such as, but not limited to cements and rubber dust.    Abatement certification is required for this item.
Recent events (5)
  • — J $18000
  • — C $18000
  • — Z $18000

1910.1200 G08

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace:   a) On or about 3/25/2013, Throughout the facility:  Material Safety Data Sheets for materials such as, but not limited to cements and rubber dust were not maintained in the facility.     Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 19, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   a) On or about 3/25/2013, Throughout the facility:  Workers were not provided with training regarding the hazards associated with materials such as, but not limited to cements and rubber dust.     Abatement certification is required for this item.
Recent events (5)
  • — J $0
  • — C $0
  • — Z $0

View American Made Tires's full OSHA safety record →