NEW YORK, NY —
OSHA Inspection: FLINTLOCK CONSTRUCTION SERVICES LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FLINTLOCK CONSTRUCTION SERVICES LLC in 325 WEST 33RD STREET, NEW YORK, NY 10001 (NAICS 236220). OSHA activity number 338970692.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLINTLOCK CONSTRUCTION SERVICES LLC
- Site address
- 325 WEST 33RD STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10001
- Mailing
- 585 NORTH BARRY AVENUE, MAMARONECK, NY 10543
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 20
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.451 B02
- Issued
- Sep 17, 2013
- Penalty
- Initial $6,160 · Current $6,160
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide. Location: 325 W 33 Street New York NY./ Front Entrance On or about: March, 21 2013 a) An employee used a single scaffold plank as a walkway while exposed to a potential fall of 9 feet to the ground below.
Recent events (3)
- — F (S) $6160
- — C (S) $6160
- — Z (S) $6160
1926.451 G02
- Issued
- Sep 17, 2013
- Penalty
- Initial $6,160 · Current $6,160
General-duty citation text
29 CFR 1926.451(g)(2): Effective September 2, 1997, the employer shall have a competent person determine the feasibility and safety of providing fall protection for employees erecting or dismantling supported scaffolds. Employers are required to provide fall protection for employees erecting or dismantling supported scaffolds where the installation and use of such protection is feasible and does not create a greater hazard. Location: 325 West 33rd Street, NY. / North side of the Building - Rear court yard On or about March 18-21, 2013 a) While erecting a tubular welded frame scaffolds employees used a vertical safety line attached to a 2 x 4 piece of wood. The 2 x 4 was installed across a window frame opening.
Recent events (3)
- — F (S) $6160
- — C (S) $6160
- — Z (S) $6160
1926.502 D15
- Issued
- Sep 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. Location: 325 West 33rd Street, NY. / North side of the Building - Rear court yard On or about March 18-21, 2013 a) While erecting a tubular welded frame scaffolds employees used a vertical safety line attached to a 2 x 4 piece of wood. The 2 x 4 was installed across a window frame opening.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.454 B01
- Issued
- Sep 17, 2013
- Abate by
- Oct 4, 2013
- Penalty
- Initial $4,400 · Current $4,400
General-duty citation text
29 CFR 1926.454(b)(1): The employer did not have each employee who is involved in erecting, disassembling, moving, operating, maintaining, or inspecting a scaffold trained by a competent person to recognize the hazards associated with the work in question. Location: 325 West 33rd Street New York, NY. / South East side of the building on or about MArch 18-21, 2013. a) Employees were not trained to recognize hazards associated with the type of scaffold being erected.
Recent events (3)
- — F (S) $4400
- — C (S) $4400
- — Z (S) $4400
1926.451 B01 I
- Issued
- Sep 17, 2013
- Penalty
- Initial $61,600 · Current $61,600
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Location: 325 West 33rd Street, NY. / Front entrance - South East side of the Building On or about March 18-21, 2013 a) Employees were installing siding from tubular welded frame scaffold that was not fully planked. The employees were exposed to a potential fall hazard of up to 26 feet to the ground below.
Recent events (3)
- — F (W) $61600
- — C (W) $61600
- — Z (W) $61600
1926.451 C01
- Issued
- Sep 17, 2013
- Penalty
- Initial $61,600 · Current $61,600
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. Location: 325 West 33rd Street New York, NY / Fron Entrance, South East Side of the Building On or about March 18-21, 2013 a) Employees were installing siding from a 32 feet high tubular welded frame scaffold that was not restrained from tipping.
Recent events (3)
- — F (W) $61600
- — C (W) $61600
- — Z (W) $61600
1926.451 E01
- Issued
- Sep 17, 2013
- Penalty
- Initial $48,400 · Current $48,400
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Location: 325 West 33rd Street New York, NY./ Front entrance, South East side of the building On or about March 18-21, 2013. a) Employees were working from a 32 feet high tubular welded frame scaffold that did not have means of of access. Employees climbed frames and crossbraces to get to work platform.
Recent events (3)
- — F (W) $48400
- — C (W) $48400
- — Z (W) $48400
1926.451 G01 VII
- Issued
- Sep 17, 2013
- Penalty
- Initial $61,600 · Current $61,600
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 325 West 33rd Street New York, NY / Front Entrance South East side of the Building On or About March 18-21, 2013 a) Employees were installing siding from a 32 feet high tubular welded frame scaffold that were not provided with a fall protection system. The employees were exposed to a potential fall hazard of up to 26 feet to the ground below.
Recent events (3)
- — F (W) $61600
- — C (W) $61600
- — Z (W) $61600
More inspections at Flintlock Construction Services LLC
View Flintlock Construction Services LLC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338970692.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.