OSHA Inspection: CA ARMY NATIONAL GUARD - CAMP ROBERTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CA ARMY NATIONAL GUARD - CAMP ROBERTS in HWY 101, PLANS, TRAINING, MOBILIZATION & SECURITY CAMP ROBERTS, SAN MIGUEL, CA 93451 (NAICS 928110). OSHA activity number 338985112.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CA Army National Guard - Camp Roberts — free Get an email when a new federal OSHA severe-injury report for CA Army National Guard - Camp Roberts is published. One employer, no account, unsubscribe in one click.
Site address
HWY 101, PLANS, TRAINING, MOBILIZATION & SECURITY CAMP ROBERTS
City
SAN MIGUEL
State
CA
ZIP
93451
Mailing
HWY 101 CAMP ROBERTS, BLDG 101, SAN MIGUEL, CA 93451
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
5
Ownership type
D

6 citations on file for this inspection.

1910.37 E

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(e): An employee alarm system must be operable. Employers must install and maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other emergencies, unless employees can promptly see or smell a fire or other hazard in time to provide adequate warning to them. The employee alarm system must comply with § 1910.165. [39 FR 23502, June 27, 1974, as amended at 45 FR 60703, Sept. 12, 1980; 67 FR 67963, Nov. 7, 2002]  Bldg. 101: On or about 26MAR13, the building did not have an employee alarm system or other procedure as required by 29 CFR 1910.165.
Recent events (1)
  • — Z (S) $0

1910.157 E02

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  (a) Bldg. 101, hallway outside DPTMS office: On or about 26MAR13, a fire extinguisher was last visually inspected in March, 2011.  (b) Bldg. 101, hallway outside conference room: On or about 26MAR13, a fire extinguisher was last visually inspected in April, 2011.
Recent events (1)
  • — Z (S) $0

1910.157 E03

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:   (a) Bldg. 101, hallway outside DPTMS office: On or about 26MAR13, a fire extinguisher's last annual maintenance inspection was March, 2011.   (b) Bldg. 101, hallway outside conference room: On or about 26MAR13, a fire extinguisher's last annual maintenance inspection was March, 2011.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Bldg. 101, conference room: On or about 26MAR13, a power strip was used to provide 120VAC electrical service to a microwave and refrigerator.
Recent events (1)
  • — Z (S) $0

1960.58

Serious Gravity 5 1 instance 60 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1960.58:  The Agency did not provide training for collateral duty safety and health personnel including all members of certified occupational safety and health committees commensurate with the scope of their assigned responsibilities:    Bldg. 101: On or about 26MAR13, the agency did not provide safety training for the recently assigned installation safety officer, or schedule training commensurate with the scope of their assigned duties.
Recent events (1)
  • — Z (S) $0

1904.32 A

Other-than-serious 1 instance 2 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a):  The employer did not certify that it examined the OSHA 300 log and that the annual summary was correct and complete:   In the alternative:   29 CFR 1960.67:  As required by 29 CFR 1904.32, the agency did not certify that it examined the OSHA 300 log and that the annual summary was correct and complete as required by 29 CFR 1904.32(a):  Bldg 101: On or about 26MAR13, the agency did not review OSHA form 300 Log of Workplace Injuries and Illnesses for the previous year, create an annual summary of injuries and illnesses recorded on the log, certify the summary, and post the summary as required in 29 CFR 1904.32(a).
Recent events (1)
  • — Z (O) $0

View CA Army National Guard - Camp Roberts's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338985112.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.