OSHA Inspection: CA ARMY NATIONAL GUARD - CAMP ROBERTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CA ARMY NATIONAL GUARD - CAMP ROBERTS in HWY 101, CIF WAREHOUSE CAMP ROBERTS, SAN MIGUEL, CA 93451 (NAICS 493110). OSHA activity number 338987878.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CA Army National Guard - Camp Roberts — free Get an email when a new federal OSHA severe-injury report for CA Army National Guard - Camp Roberts is published. One employer, no account, unsubscribe in one click.
Site address
HWY 101, CIF WAREHOUSE CAMP ROBERTS
City
SAN MIGUEL
State
CA
ZIP
93451
Mailing
HWY 101 CAMP ROBERTS, BLDG 101, SAN MIGUEL, CA 93451
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
5
Ownership type
D

8 citations on file for this inspection.

1910.36 E

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.36(e): A side-hinged exit door must be used.  Boot room: On or about 26MAR13, a vertical rolling door was designated as an emergency exit door.
Recent events (1)
  • — Z (S) $0

1910.37 E

Serious Gravity 5 1 instance 7 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(e): An employee alarm system must be operable. Employers must install and maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other emergencies, unless employees can promptly see or smell a fire or other hazard in time to provide adequate warning to them. The employee alarm system must comply with § 1910.165.   [39 FR 23502, June 27, 1974, as amended at 45 FR 60703, Sept. 12, 1980; 67 FR 67963, Nov. 7, 2002]  Bldg. 932: On or about 26MAR13, the building did not have an employee alarm system or other procedure as required by 29 CFR 1910.165.
Recent events (1)
  • — Z (S) $0

1910.157 C04

Serious Gravity 5 3 instances 7 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not kept in their designated places when not being used:  (a) Front Door: On or about 26MAR13, a fire extinguisher was kept in the recessed portions of the walls between support studs as a substitute for a designated hook.   (b) Side Door: On or about 26MAR13, a fire extinguisher was kept on the floor.  (c) Battery Charging Station: On or about 26MAR13, a fire extinguisher was kept on the floor.
Recent events (1)
  • — Z (S) $0

1910.157 E02

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:   Bldg. 932, Side Door: On or about 26MAR13, a fire extinguisher was last visually inspected March, 2012.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   Office #2: On or about 26MAR13, a power strip was used to provide 120VAC electrical service to a refrigerator.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 7 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   Wall of conference room: On or about 26MAR13, access to an electrical panel was obstructed by a large container.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Flexible cords and cables were not used as permitted by 29 CFR 1910.305(g)(1)(iv)(A) through (F):   Battery charging station: On or about 26MAR13, a flexible cord was run through steel loops on the wall.
Recent events (1)
  • — Z (S) $0

1904.32 A

Other-than-serious 1 instance 2 exposed
Issued
Apr 15, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a):  The employer did not certify that it examined the OSHA 300 log and that the annual summary was correct and complete:  In the alternative:  29 CFR 1960.67:  As required by 29 CFR 1904.32(a), the agency did not certify that it examined the OSHA 300 log and that the annual summary was correct and complete as required by 29 CFR 1904.32(a):  Bldg 932: On or about 26MAR13, the agency did not review OSHA form 300 Log of Workplace Injuries and Illnesses for the previous year, create an annual summary of injuries and illnesses recorded on the log, certify the summary, and post the summary as required in 29 CFR 1904.32(a).
Recent events (1)
  • — Z (O) $0

View CA Army National Guard - Camp Roberts's full OSHA safety record →