SAN MIGUEL, CA —
OSHA Inspection: CA ARMY NATIONAL GUARD - CAMP ROBERTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CA ARMY NATIONAL GUARD - CAMP ROBERTS in HWY 101, BLDG 832, TRAINING SUPPORT CENTER CAMP ROBERTS, SAN MIGUEL, CA 93451 (NAICS 493110). OSHA activity number 338990559.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CA ARMY NATIONAL GUARD - CAMP ROBERTS
- Site address
- HWY 101, BLDG 832, TRAINING SUPPORT CENTER CAMP ROBERTS
- City
- SAN MIGUEL
- State
- CA
- ZIP
- 93451
- Mailing
- HWY 101 CAMP ROBERTS, BLDG 101, SAN MIGUEL, CA 93451
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 6
- Ownership type
- D
Citations
9 citations on file for this inspection.
1910.22 D01
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. Main Bay - On or about 28MAR13, the upper level of the shop was used for material storage without posting the load limit plate.
Recent events (1)
- — Z (S) $0
1910.23 A08
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: Main Bay - On or about 28MAR13, employees were exposed to accidentally walk into eight inch wide holes between the edge of the platform and the walls of the building where the employer did not protect the holes with covers or railings.
Recent events (1)
- — Z (S) $0
1910.23 C01
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Main Bay - On or about 28MAR13, employees were exposed to fall hazards while walking and working on an open platform without rails approximately nine feet above the lower level, employees were also exposed to struck by hazards at the entrance of the hallway and storage room when passing beneath the upper level where toe boards were not used to prevent objects from falling form the open platform.
Recent events (1)
- — Z (S) $0
1910.37 A03
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: Room 109: On or about 28MAR13, a heavy canvas curtain was partially obstructing an emergency exit doorway.
Recent events (1)
- — Z (S) $0
1910.157 C04
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not kept in their designated places when not being used: Room 107: On or about 28MAR13, a fire extinguisher was not available for use at the designated and marked location.
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Exposure adjustment: Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.) Room 111: On or about 28MAR13, at approximately 2:34 pm, the tongue guard was not adjusted to within on quarter inch of the grinding wheel surface when used by the employees.
Recent events (1)
- — Z (S) $0
1910.304 F01 VIII
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits shall be listed and marked "SWD." Room 113: On or about 28MAR13, the lights in the main bay are controlled by breakers in the 832 panel, the breakers are not marked SWD for switch duty for use as light switches.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and cables were not used as permitted by 29 CFR 1910.305(g)(1)(iv)(A) through (F): (a) Room 102: On or about 28MAR13, a flexible cord was run under a desk leg where the weight of the desk bore upon the cord that provided electrical service to office equipment. (b) Room 101: On or about 28MAR13, a flexible cord was run through a hole in the wall to provide electrical service to appliances.
Recent events (1)
- — Z (S) $0
1904.32 A
- Issued
- Apr 16, 2013
- Abate by
- May 10, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.32(a): The employer did not certify that it examined the OSHA 300 log and that the annual summary was correct and complete: In the alternative: 29 CFR 1960.67: As required by 29 CFR 1904.32, the agency did not certify that it examined the OSHA 300 log and that the annual summary was correct and complete as required by 29 CFR 1904.32(a): Bldg 14301: On or about 28MAR13, the agency did not review OSHA form 300 Log of Workplace Injuries and Illnesses for the previous year, create an annual summary of injuries and illnesses recorded on the log, certify the summary, and post the summary as required in 29 CFR 1904.32(a).
Recent events (1)
- — Z (O) $0
More inspections at CA Army National Guard - Camp Roberts
View CA Army National Guard - Camp Roberts's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338990559.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.