Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: NATIONAL PARK SERVICE CHANNEL ISLANDS NATIONAL PARK

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE CHANNEL ISLANDS NATIONAL PARK in ANACAPA ISLAND NATIONAL PARK, VENTURA, CA 93001 (NAICS 712190). OSHA activity number 338991003.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Park Service Channel Islands National Park for free Get an email when a new federal OSHA severe-injury report for National Park Service Channel Islands National Park is published. One employer, no account, unsubscribe in one click.
Site address
ANACAPA ISLAND NATIONAL PARK
City
VENTURA
State
CA
ZIP
93001
Mailing
1901 SPINNAKER DRIVE, VENTURA, CA 93001
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
31
Ownership type
Federal government (D)

8 citations on file for this inspection.

1910.23 A08

Serious Gravity 5 1 instance 1 exposed
Issued
May 31, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:  Water house - On or about 4/3/2013, multiple floor holes were not guarded, posing a hazard for personnel.
Recent events (1)
  • · Z (S) $0

1910.101 B

Serious Gravity 5 3 instances 10 exposed
Issued
May 31, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  a) Shop - On or about 4/3/2013, the label and stencils of compressed gas cylinders were illegible due to corrosion and dirt.  b) Shop - On or about 4/3/2013, the cylinder storage area was not prominently posted with the names of the gases to be stored.   c) Shop - On or about 4/3/2013, an acetylene compressed gas cylinder was not secured from falling.
Recent events (1)
  • · Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
May 31, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   Battery house - On or about 4/3/2013, an outdoor lead acid battery area did not have an accessible emergency shower and eyewash station.
Recent events (1)
  • · Z (S) $0

1910.157 E02

Serious Gravity 5 4 instances 10 exposed
Issued
May 31, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:   a) Shop - On or about 4/3/2013, a fire extinguisher was not visually inspected monthly.   b) Visitor center - On or about 4/3/2013, a fire extinguisher was not visually inspected monthly.   c) SAR cache - On or about 4/3/2013, a fire extinguisher was not visually inspected monthly.   d) Battery house - On or about 4/3/2013, a fire extinguisher was not visually inspected monthly.
Recent events (1)
  • · Z (S) $0

1910.176 B

Serious Gravity 5 3 instances 3 exposed
Issued
May 31, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b): Storage of material created a hazard:  a) Shop - On or about 4/3/2013, boxes were stored on top of a cabinet in an unstable manner.  b) Shop - On or about 4/3/2013, gardening tools were not stored securely to prevent sliding or falling.  c) Water house - On or about 4/3/2013, a tripod was not stored securely from sliding or falling.
Recent events (1)
  • · Z (S) $0

1910.303 G01 II

Serious Gravity 5 3 instances 3 exposed
Issued
May 31, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   a) Shop - On or about 4/3/2013, the area in front of electrical panels was used for storage.   b) Shop - On or about 4/3/2013, the area in front of electrical switchboxes was used for storage.
Recent events (1)
  • · Z (S) $0

1910.305 J02 IV

Serious Gravity 5 2 instances 10 exposed
Issued
May 31, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:  a) Bunkhouse kitchen - On or about 4/3/2013, an electrical outlet near a sink was not protected by GFCI.   b) Bunkhouse restroom - On or about 4/3/2013, an electrical outlet near a sink was not protected by GFCI.
Recent events (1)
  • · Z (S) $0

1910.1200 F05 I

Serious Gravity 1 2 instances 6 exposed
Issued
May 31, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  a) Shop - On or about 4/3/2013, a spray bottle was mislabeled with its chemical contents.   b) Bunkhouse - On or about 4/3/2013, a spray bottle was not labeled with its chemical contents.
Recent events (1)
  • · Z (S) $0

View National Park Service Channel Islands National Park's full OSHA safety record →