Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WATERSIDE CONSTRUCTION, L.L.C.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WATERSIDE CONSTRUCTION, L.L.C. in RIVER ROAD & VREELAND TERRACE, EDGEWATER, NJ 07020 (NAICS 238910). OSHA activity number 338999659.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Waterside Construction, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Waterside Construction, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
RIVER ROAD & VREELAND TERRACE
City
EDGEWATER
State
NJ
ZIP
07020
Mailing
P/O BOX 36, 22 ROUTE 5, EDGEWATER, NJ 07020
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
5
Ownership type
A

10 citations on file for this inspection.

1926.350 A09

Serious Gravity 5 35 instances 2 exposed
Issued
Sep 27, 2013
Penalty
Initial $4,620 · Current $1,848 Reduced
29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position:     (a)  Apartment Building Area:  The compressed gas cylinders were not secured, on or about 4/10/2013.     (b)  West End of Site:  The fuel gas cylinder with the regulator and gauge and hose installed was lying on the ground.  The cylinders were not secured in an upright position, on or about 4/10/2013.     c)  Apartment Building, Parking Area:  The compressed gas cylinders were not secured, on or about 6/28/2013.
Recent events (3)
  • — F (S) $1848
  • — C (S) $4620
  • — Z (S) $4620

1926.350 A10

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 27, 2013
Penalty
Initial $5,390 · Current $2,156 Reduced
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour:    a)  West Side of Site:  Acetylene cylinders were stored adjacent to oxygen cylinders, on or about 4/10/2013.    b)  Apartment Building, Parking Area:  Acetylene cylinders were stored adjacent to oxygen cylinders, on or about 6/28/2013.
Recent events (3)
  • — F (S) $2156
  • — C (S) $5390
  • — Z (S) $5390

1926.453 B02 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 27, 2013
Penalty
Initial $5,390 · Current $2,156 Reduced
29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were sitting or climbing on the edge of the basket:     (a)  East End of Site:  Worker inside of the elevated aerial lift bucket climbed on to and was standing on the basket railings.  He was not standing firmly on the basket floor, on or about 6/4/2013.
Recent events (3)
  • — F (S) $2156
  • — C (S) $5390
  • — Z (S) $5390

1926.453 B02 V

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 27, 2013
Penalty
Initial $5,390 · Current $2,156 Reduced
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift:     (a)  East End of Site:  Worker inside of the elevated aerial lift bucket was not protected from falling.  Worker was not wearing fall protection, on or about 6/4/2013.
Recent events (3)
  • — F (S) $2156
  • — C (S) $5390
  • — Z (S) $5390

1926.501 B01

Serious Gravity 10 2 instances 3 exposed
Issued
Sep 27, 2013
Penalty
Initial $5,390 · Current $2,156 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:      a)  East End of Site, Roof Area:  Two workers on the roof were not protected from falling approximately 30 feet.  Their harness lanyards were not secured to any anchor point, on or about 6/4/2013.      b)  East End of Site, Floor Area:  The worker using the water hose during the floor demolition was not protected from falling approximately 15 feet.  The harness lanyard was not secured to any anchor point, on or about 6/14/2013.
Recent events (3)
  • — R (S) $2156
  • — C (S) $5390
  • — Z (S) $5390

1926.850 A

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 27, 2013
Penalty
Initial $5,390 · Current $2,156 Reduced
29 CFR 1926.850(a): Evidence in writing was not available that an engineering survey performed by a competent person had been performed prior to permitting employee(s) to start demolition operations:     (a)  Throughout Site:  An engineering survey was not available for the manufacturing building being demolished, on or about 4/10/2013.
Recent events (3)
  • — F (S) $2156
  • — C (S) $5390
  • — Z (S) $5390

1926.850 I

Serious Gravity 10 6 instances 3 exposed
Issued
Sep 27, 2013
Penalty
Initial $7,000 · Current $2,800 Reduced
29 CFR 1926.850(i): Floor openings, not used as material drops, were not covered with a material substantial enough to support the weight of the load to be imposed:    (a) Throughout Site:  The floor holes were not covered, on or about 4/10/2013.
Recent events (3)
  • — F (S) $2800
  • — C (S) $7000
  • — Z (S) $7000

1926.856 B

Serious Gravity 10 6 instances 3 exposed
Issued
Sep 27, 2013
Penalty
Initial $7,000 · Current $2,800 Reduced
29 CFR 1926.856(b): During demolition operation(s), floor openings did not have curbs or stop-logs to prevent the mechanical equipment from running over the edge:     (a)  Throughout Site:  Mechanical equipment such as but not limited to a man lift and a rough terrain powered truck were in use on site.  The floor holes were not provided with stop logs or curbs, on or about 4/10/2013.
Recent events (3)
  • — F (S) $2800
  • — C (S) $7000
  • — Z (S) $7000

1926.858 D

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 27, 2013
Penalty
Initial $5,390 · Current $2,156 Reduced
29 CFR 1926.858(d): Any structural member being dismembered shall not be overstressed:     a)  East Side of Site:  A steel joist was torch cut where is was overstressed and broke.  A steel joist gave way onto workers who were elevated in a man-lift, on or about 4/10/2013.
Recent events (3)
  • — F (S) $2156
  • — C (S) $5390
  • — Z (S) $5390

1926.859 G

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 27, 2013
Penalty
Initial $5,390 · Current $2,156 Reduced
29 CFR 1926.859(g): During demolition, continuing inspections by a competent person shall be made as the work progresses to detect hazards resulting from weakened or deteriorated floors, or walls, or loosened material. No employee shall be permitted to work where such hazards exist until they are corrected by shoring, bracing, or other effective means:       a)  East End of Site:  A competent person did not perform continuing inspections to determine if a hazardous condition was present when workers torch cut steel joists.  A steel joist gave way onto workers who were working elevated in a man-lift, on or about 4/10/2013.
Recent events (3)
  • — F (S) $2156
  • — C (S) $5390
  • — Z (S) $5390

View Waterside Construction, L.L.C.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338999659.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.