BARBOURSVILLE, WV —
OSHA Inspection: ADAMS TRUCKING & SUPPLY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADAMS TRUCKING & SUPPLY, INC. in 3700 ROUTE 60 EAST, BARBOURSVILLE, WV 25504 (NAICS 327320). OSHA activity number 339008112.
Where did this inspection happen?
- Establishment
- ADAMS TRUCKING & SUPPLY, INC.
- Site address
- 3700 ROUTE 60 EAST
- City
- BARBOURSVILLE
- State
- WV
- ZIP
- 25504
- Mailing
- 3700 ROUTE 60 EAST, BARBOURSVILLE, WV 25504
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 45
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1575.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) Mechanic Garage: Employees operate a Delta ShopMaster abrasive pedestal grinder (model #GR250, serial #046960W4031) that had a maximum opening of 1/2 of an inch from the grinding wheel to the work rest, as observed on April 10, 2013. Abatement Certification Required for this Item.
Recent events (2)
- — I (S) $1575
- — Z (S) $2100
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Mechanic Garage: Employees operate a Delta ShopMaster abrasive pedestal grinder (model #GR250, serial #046960W4031) that had a maximum opening of 1/2 of an inch from the grinding wheel and the tongue guard, as observed on April 10, 2013. Abatement Certification Required for this Item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) Blue Storage Building: The exit route to the southwest corner exit door was blocked by a 4 foot by 3 foot pallet containing supplies, as observed on April 10, 2013. Abatement Certification Required for this Item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at ADAMS TRUCKING & SUPPLY, INC.
HUNTINGTON, WV—2023-08-09 00:00:00
ADAMS TRUCKING & SUPPLY, INC.
BARBOURSVILLE, WV—2010-05-20 00:00:00
ADAMS TRUCKING & SUPPLY, INC.
BARBOURSVILLE, WV—2007-05-23 00:00:00
ADAMS TRUCKING & SUPPLY, INC.
BARBOURSVILLE, WV—2007-05-11 00:00:00
ADAMS TRUCKING & SUPPLY, INC.
BARBOURSVILLE, WV—2004-07-13 00:00:00
ADAMS TRUCKING & SUPPLY, INC.
View ADAMS TRUCKING & SUPPLY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327320)
RENO, NV—2026-07-09
R&K READY MIXED CONCRETE, LLC
RENO, NV—2026-07-09
R&K READY MIXED CONCRETE, LLC
MOUNT VERNON, IL—2026-07-08
BEELMAN READY-MIX INC
STOCKTON, CA—2026-07-07
A & A CONCRETE SUPPLY, INC.
LA CROSSE, WI—2026-07-07
RIVER CITY READY MIX, INC.
More inspections in WV
CHARLESTON, WV—2026-07-15
ASTECH CORPORATION
PARKERSBURG, WV—2026-07-15
UNKNOWN
VIENNA, WV—2026-07-15
PHOENIX ASSOCIATES, INC.
BRIDGEPORT, WV—2026-07-14
MID ATLANTIC METALWORKS INC.
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339008112.