EDGEWATER, NJ —
OSHA Inspection: WATERSIDE CONSTRUCTION, L.L.C.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WATERSIDE CONSTRUCTION, L.L.C. in RIVER ROAD & VREELAND TERRACE, EDGEWATER, NJ 07020 (NAICS 238910). OSHA activity number 339064040.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WATERSIDE CONSTRUCTION, L.L.C.
- Site address
- RIVER ROAD & VREELAND TERRACE
- City
- EDGEWATER
- State
- NJ
- ZIP
- 07020
- Mailing
- P/O BOX 36 22 ROUTE 5, EDGEWATER, NJ 07020
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.62 D01 I
- Issued
- Sep 27, 2013
- Penalty
- Initial $5,390 · Current $2,156 Reduced
BWPB
General-duty citation text
29 CFR 1926.62(d)(1)(i): Each employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employee was exposed to lead at or above the action level of 30 micrograms per cubic meter of air (30 ug/m3) calculated as an 8-hour time-weighted average (TWA): a) Vreeland and River Rd, Edgewater: Employer did not initially determine employees exposure levels to lead where employees were involved in torch burning steel beams and steel frames containing lead based paints during the demolition of a building, on or about 5/13/2013
Recent events (3)
- — F (S) $2156
- — C (S) $5390
- — Z (S) $5390
1910.134 E01
- Issued
- Sep 27, 2013
- Penalty
- Initial $3,850 · Current $1,540 Reduced
1591BWPB
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Vreeland and River Road: The employer did not provide a medical evaluation for the employees who were required to wear respirators while torch cutting steel beams and steel frames, on or about 4/8/2013.
Recent events (3)
- — F (S) $1540
- — C (S) $3850
- — Z (S) $3850
1926.62 D02 V E
- Issued
- Sep 27, 2013
- Penalty
- Initial $5,390 · Current $2,156 Reduced
General-duty citation text
29 CFR 1926.62(d)(2)(v)(E): Employer did not conduct biological monitoring in accordance with paragraph (j)(1)(i) of this section, to consist of blood sampling and analysis for lead and Zinc Protoporphyrin levels a) Vreeland and River Rd, Edgewater: The employer did not provide employees with Biological monitoring, where the employees' initial exposure assessment was not performed, on or about 5/13/2013.
Recent events (3)
- — F (S) $2156
- — C (S) $5390
- — Z (S) $5390
1926.62 L02 VIII
- Issued
- Sep 27, 2013
- Abate by
- Nov 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.62(l)(2)(viii): The employee's right of access to records under 29 CFR 1910.1020 (g)(1)(iii): a) Vreeland and River Rd, Edgewater: The employer did not inform employees of their rights to access their exposure records, following air sampling that was conducted for lead, on or about 6/13/2013.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.134 F
- Issued
- Sep 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f): The employee was required to use a respirator without being fit tested with the same make, model, style and size of respirator that was to be used: (Construction Reference 1926.103) a) Vreeland and River Rd, Edgewater: Employees, who were involved in torch cutting steel columns and frames that were painted with lead based paints, were required to wear North 5500 half-face respirator without being fit tested, on or about 5/13/2013.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Waterside Construction, L.L.C.
View Waterside Construction, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339064040.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.