Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DYNAMIC DESIGN & MANUFACTURING, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of DYNAMIC DESIGN & MANUFACTURING, INC. in 6321 MONARCH PARK PL., NIWOT, CO 80504 (NAICS 332322). OSHA activity number 339080087.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dynamic Design & Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Dynamic Design & Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6321 MONARCH PARK PL.
City
NIWOT
State
CO
ZIP
80504
Mailing
6321 MONARCH PARK PL., NIWOT, CO 80504
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
34
Ownership type
A

2 citations on file for this inspection.

1910.1026 L02 I A

Other-than-serious 1 instance 1 exposed
Issued
Sep 4, 2013
Abate by
Oct 9, 2013
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.1026(l)(2)(i)(A): The employer did not provide appropriate information and training for all employees exposed to chromium (VI), in that employees could not demonstrate knowledge of the contents of the Chromium (VI) standard:     (a)   Dynamic Design & Manufacturing, Inc., 6321 Monarch Park Pl., Niwot, CO 80504:  The employer did not ensure that each employee could demonstrate knowledge of the contents of this section in that employees did not receive specific training on the health hazards of hexavalent chromium.  This condition exposed employees to a Cr(VI) hazard.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (S) $1785

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Sep 4, 2013
Abate by
Oct 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D when the employer determined that any voluntary respirator use was permissible:    (a)        Dynamic Design & Manufacturing, Inc., 6321 Monarch Park Pl., Niwot, CO 80504:  On and before May 22, 2013, the employer provides N95 respirators to employees for voluntary use. The employer did not provide employees with the information contained in Appendix D.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dynamic Design & Manufacturing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339080087.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.