Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: TANMAR COMPANIES, L.L.C.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TANMAR COMPANIES, L.L.C. in RIG 393, ST W LEASE, WELL #4302H, MIDLAND, TX 79705 (NAICS 213112). OSHA activity number 339085417.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tanmar Companies, L.L.C. for free Get an email when a new federal OSHA severe-injury report for Tanmar Companies, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
RIG 393, ST W LEASE, WELL #4302H
City
MIDLAND
State
TX
ZIP
79705
Mailing
2700 ELKINS ROAD, MIDLAND, TX 79705
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
2
Ownership type
Private (A)

3 citations on file for this inspection.

1910.305 D02

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 17, 2013
Abate by
Jun 21, 2013
Penalty
Initial $4,900 · Current $3,430 Reduced
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.    On or about May 22, 2013, the Industrial Control Panel on the left side of the Directional Driller Trailer was missing a dead front. Three-600V nominal and three 120 V nominal cables going into the box were exposed. The control box lid was taped opened to the side of the trailer to allow one 600V nominal cable to be spliced into the control box and to not pinch the cord between the box and lid. This condition exposed employees to electrical shock and electrocution hazards.
Recent events (2)
  • · I (S) $3430
  • · Z (S) $4900

1910.334 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 17, 2013
Abate by
Jun 21, 2013
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.334(a)(1): Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation:    On or about May 22, 2013, below the Mud Engineers and Directional Driller's Trailer, two 50-foot electrical extension cords were run underneath the trailer floor, the cords were held up with chicken wire. One extension cord showed physical damage made by the chicken wiring cutting into the outer insulation. This condition exposed employees to electrical burn and shock hazards.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

1910.334 A02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 17, 2013
Abate by
Jun 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On or about May 22, 2013, behind the Mud Engineer's and Directional Driller's Trailer, the electrical cable to the water pump sitting inside the containment box was pinched between the lid and the wall of the containment box. This condition exposed employees to electrical burn and shock hazards.