WASHINGTON, DC ·
OSHA Inspection: HERNANDEZ CONSTRUCTION
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of HERNANDEZ CONSTRUCTION in 610/612 M STREET, NW, WASHINGTON, DC 20016 (NAICS 238140). OSHA activity number 339092561.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HERNANDEZ CONSTRUCTION
- Site address
- 610/612 M STREET, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 14420 NEW HAMPSHIRE AVENUE, SILVER SPRING, MD 20904
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.451 F16
- Issued
- Jun 27, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(f)(16): Platforms shall not deflect more than 1/60 of the span when loaded. a) South Side of the Building, #612, 2nd Floor - A mason foreman was working on a tubular welded frame scaffold which was deflecting several inches from being overloaded exposing him to a 30 foot fall hazard, on or about 05/30/13. Abatement Certification Required
Recent events (1)
- · Z (S) $2000
1926.451 G01
- Issued
- Jun 27, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) South Side of the Building, #612, 2nd Floor - A mason foreman was working on a tubular welded frame scaffold which was not equipped with guard rails exposing him to a 30 foot fall hazard, on or about 05/30/13. Abatement Certification Required
Recent events (1)
- · Z (S) $2000
1926.452 C02
- Issued
- Jun 27, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. a) South Side of the Building, #612, 2nd Floor - A mason foreman was working on a tubular welded frame scaffold which was missing cross braces exposing him to a 30 foot fall hazard, on or about 05/30/13. Abatement Certification Required
Recent events (1)
- · Z (S) $2000
1926.501 B13
- Issued
- Jun 27, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) North Side of the Building, #612 - A mason foremen was observed using an unguarded the ramp to enter and exit the building exposing him to a 9 foot fall onto the basement patio deck, on or about 05/30/13. b) South Side of the Building, #612, 2nd Floor - A mason foreman and helpers were observed working near an unguarded window/door opening exposing him to a 16 foot fall hazard, on or about 05/30/13. No Abatement Documentation Or Certification Required
Recent events (1)
- · Z (S) $1600
More inspections at Hernandez Construction
View Hernandez Construction's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339092561.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.