SAN BERNARDINO, CA ·
OSHA Inspection: USDA FOREST SERVICE - SAN BERNARDINO NF
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of USDA FOREST SERVICE - SAN BERNARDINO NF in 2065 E. PERIMETER RD AIR TANKER BASE, SAN BERNARDINO, CA 92408 (NAICS 922160). OSHA activity number 339119042.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- USDA FOREST SERVICE - SAN BERNARDINO NF
- Site address
- 2065 E. PERIMETER RD AIR TANKER BASE
- City
- SAN BERNARDINO
- State
- CA
- ZIP
- 92408
- Mailing
- 602 S. TIPPECANOE AVE, SAN BERNARDINO, CA 92408
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922160
- Employees
- 10
- Ownership type
- Federal government (D)
Citations
9 citations on file for this inspection.
1910.22 D01
- Issued
- Jul 3, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. Garage: On or about 03JUN13, the upper level of the shop was used for material storage without posting the load limit plate.
Recent events (1)
- · Z (S) $0
1910.23 C01
- Issued
- Jul 3, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Garage: On or about 03JUN13, employees were exposed to struck by hazards at the entrance of the offices and storage room when passing beneath the upper level where toe boards were not used to prevent objects from falling from the open platform.
Recent events (1)
- · Z (S) $0
1910.157 C04
- Issued
- Jul 3, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not kept in their designated places when not being used: Garage: On or about 03JUN13, three fire extinguishers were on the floor or setting on tables and not mounted in a designated location, exposing employees to delay in locating the fire extinguisher in the event of fire.
Recent events (1)
- · Z (S) $0
1910.178 A04
- Issued
- Jul 3, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: Garage: On or about 03JUN13, the employer provided a maintenance platform for attachment to a forklift to lift employees to an upper level in the garage.
Recent events (1)
- · Z (S) $0
1910.303 B01
- Issued
- Jul 3, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1): Outside electrical room: On or about 3JUN13, an outside light control panel used by employees was located inside an electrical enclosure with exposed electrical conductors.
Recent events (1)
- · Z (S) $0
1910.303 B02
- Issued
- Jul 3, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Garage: On or about 03JUN13, two flexible cord sets were connected in series to provide 120VAC service to a treadmill.
Recent events (1)
- · Z (S) $0
1910.303 B07 IV
- Issued
- Jul 3, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: Garage: On or about 03JUN13, four receptacle outlets had broken plastic receivers.
Recent events (1)
- · Z (S) $0
1910.305 G01 IV C
- Issued
- Jul 3, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows, or similar openings: Garage: On or about 3JUN13, a flexible cord providing 120VAC service to a scissor lift was run under a vertical door.
Recent events (1)
- · Z (S) $0
1910.334 A02 II
- Issued
- Jul 3, 2013
- Abate by
- Jul 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made. Garage: On or about 3JUN13, a flexible cord providing 120VAC service to a scissor lift was worn and frayed exposing employees to electrical shock.
Recent events (1)
- · Z (S) $0
More inspections at Usda Forest Service - SAN Bernardino NF
View Usda Forest Service - SAN Bernardino NF's full OSHA safety record →
More inspections in this industry (NAICS 922160)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339119042.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.