Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRICON TIMBER, LLC

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of TRICON TIMBER, LLC in 162 OLD MILL LOOP, SAINT REGIS, MT 59866 (NAICS 321113). OSHA activity number 339119679.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tricon Timber, LLC — free Get an email when a new federal OSHA severe-injury report for Tricon Timber, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TRICON TIMBER, LLC
Site address
162 OLD MILL LOOP
City
SAINT REGIS
State
MT
ZIP
59866
Mailing
162 OLD MILL LOOP, SAINT REGIS, MT 59866
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
185
Ownership type
A

2 citations on file for this inspection.

1910.95 G06

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 27, 2013
Abate by
Jul 17, 2013
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels :   (a) At the facility: On or about 11 June 2013 and at times prior the Employer did not ensure that all employees included in the Company hearing conservation program obtained the annual audiogram.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4500

1910.253 B04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 27, 2013
Abate by
Jul 17, 2013
Penalty
Initial $4,500 · Current $2,250 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    (a) Fabrication Shop: On or about 11 June 2013 and at times prior the employer stored oxygen and acetylene in the same area thereby exposing employees to fire hazards.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

View Tricon Timber, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339119679.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.