Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: WALMART ASSOCIATES INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of WALMART ASSOCIATES INC. in 3803 OSBORNE DR. W., HASTINGS, NE 68901 (NAICS 452910). OSHA activity number 339132318.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Walmart Associates INC. for free Get an email when a new federal OSHA severe-injury report for Walmart Associates INC. is published. One employer, no account, unsubscribe in one click.
Site address
3803 OSBORNE DR. W.
City
HASTINGS
State
NE
ZIP
68901
Mailing
3803 OSBORNE DR. W., HASTINGS, NE 68901
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452910
Employees
170
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A05

Other-than-serious 1 instance 3 exposed
Issued
Jul 30, 2013
Abate by
Aug 23, 2013
Penalty
Initial $4,000 · Current $2,200 Reduced
29 CFR 1910.212(a)(5):     Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:     In the Tire Lube Express (TLE) pit area the employer is failing to ensure that the 4 ceiling mounted heater fans were provided with guards that have an opening no larger than one-half inch.
Recent events (2)
  • · I (O) $2200
  • · Z (S) $4000

1910.303 G01

Other-than-serious 1 instance 3 exposed
Issued
Jul 30, 2013
Abate by
Aug 23, 2013
Penalty
Initial $3,000 · Current $2,200 Reduced
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:      In front of the door to the computer room and inside the computer room behind the customer service area the employer is failing to ensure that the 3 shopping carts full of merchandise and a chair with a box of papers was not blocking access to the breaker panel located within the computer room on the back wall.
Recent events (2)
  • · I (O) $2200
  • · Z (S) $3000

1910.334 A03 I

Other-than-serious 1 instance 4 exposed
Issued
Jul 30, 2013
Abate by
Aug 23, 2013
Penalty
Initial $4,000 · Current $2,200 Reduced
29 CFR 1910.334(a)(3)(i):       Flexible cord used with grounding type equipment will contain an equipment grounding conductor.        In the Tire Lube Express (TLE) area the employer is failing to ensure that electrical equipment was free from recognized hazards in that the Maxx Air high velocity fan plug was missing the grounding pin.
Recent events (2)
  • · I (O) $2200
  • · Z (S) $4000

View Walmart Associates INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339132318.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.