OSHA Inspection: KOSWIRE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KOSWIRE, INC. in 4600 CANTRELL ROAD, FLOWERY BRANCH, GA 30542 (NAICS 331222). OSHA activity number 339146011.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Koswire, INC. — free Get an email when a new federal OSHA severe-injury report for Koswire, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
KOSWIRE, INC.
Site address
4600 CANTRELL ROAD
City
FLOWERY BRANCH
State
GA
ZIP
30542
Mailing
4600 CANTRELL ROAD, FLOWERY BRANCH, GA 30542
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331222
Employees
52
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 45 exposed
Issued
Aug 22, 2013
Abate by
Sep 26, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about 06/26/2013 at 6400 Cantrell Road Flowery Branch, GA; employees performing tool and die changes and cleaning operations of machines including but not limited to the number 1 wire draw line did not effectively lock out the line and depended solely on the interlock system exposing them to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.147 D04 I

Deleted Serious Gravity 10 1 instance 45 exposed
Issued
Aug 22, 2013
Abate by
Sep 26, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about 06/26/2013 at 6400 Cantrell Road Flowery Branch, GA; employees performing tool and die changes and cleaning operations of machines including but not limited to the number 1 wire draw line did not apply locks to the lines and depended solely on the interlock system exposing them to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 22, 2013
Abate by
Sep 6, 2013
Penalty
Initial $5,500 · Current $3,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about 6/26/2013 at 4600 Cantrell Road Flowery Branch, GA; employees performing plasma cutting operations were exposed to 240V electrical hazards where the metallic box used as a pendant to power the plasma cutter was not used as it was intended by the manufacturer.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5500

1910.303 G01 I A

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 22, 2013
Abate by
Sep 6, 2013
Penalty
Initial $2,805 · Current $2,500 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening whwere they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  On or about 6/26/2013 at 6400 Cantrell Road Flowery Branch, GA; employees were potentially exposed to electrical hazards where the 240V electrical panel that powered the air conditioning units for the office was blocked.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $2805

1910.147 C07 I B

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 22, 2013
Abate by
Sep 26, 2013
Penalty
Initial $38,500 · Current $7,000 Reduced
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:    On or about 7/8/2013 at 4600 Cantrell Road Flowery Branch, GA; an affected employee was observed performing cleaning operations of the number 1 wire draw line without the use of locks and relied on the interlock system for the control of energy.    Koswire, Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 880563, citation number 1, item number 1 and was affirmed as a final order on 4/5/2013, with respect to a workplace located at 4600 Cantrell Road Flowery Branch, GA.