Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARGUETA CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARGUETA CONSTRUCTION LLC in 2345 NEBRASKA AVE. NW, WASHINGTON, DC 20016 (NAICS 236118). OSHA activity number 339152092.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Argueta Construction LLC — free Get an email when a new federal OSHA severe-injury report for Argueta Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
2345 NEBRASKA AVE. NW
City
WASHINGTON
State
DC
ZIP
20016
Mailing
4095 GEORGE MASON DR., ARLINGTON, VA 22204
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 4 instances 2 exposed
Issued
Aug 15, 2013
Abate by
Aug 21, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:    a) Top Level, Center of Structure - Workers standing on the top of a wall frame using a pneumatic nail gun to fasten the top plate to the frame, were not protected from falling 8 feet to the plywood sub-floor and scrap material below on or about 6/27/2013.       b) First Level, Center of Structure - Workers constructing interior 2x4 wood frames or obtaining materials would walk by or over openings in the floor where the plywood sub-floor had not been placed, were not protected from stepping into or through the holes on or about 6/27/2013.     c) Front Entrance Way of Structure - Workers  walked on a ramp to cross over a 4' wide, 6' deep opening when entering the structure, were not protected from falling to the concrete slab below on or about 6/27/2013 .     d) First Floor Level, Front Right of Structure - Workers building interior 2x4 wood wall frames near a floor to ceiling high, 32" wide wall opening were not protected from falling 8' through the opening to the concrete driveway directly below on or about 6/27/2013.           Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.701 B

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 15, 2013
Abate by
Aug 21, 2013
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement.      a) Foundation Wall, Front of Structure - 4" long threaded rebar, placed approximately 2' apart, was protruding and unguarded when crossing over the foundation to enter the structure or when working around the foundation on or about 6/27/2013.        Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.1052 C01 I

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 15, 2013
Abate by
Aug 21, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:     a) First Level Center and Lower Level Front Right Side - Five step stairway used by workers to gain access to raised section on the first level and seven step stairway used by workers to gain access to the first level from the garage on or about 6/27/2013.       Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.1052 C01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 15, 2013
Abate by
Aug 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge.   a) First Level Center and Lower Level Front Right Side - Five step stairway used by workers to gain access to raised section on the first level and seven step stairway used by workers to gain access to the first level from the garage on or about 6/27/2013.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Argueta Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339152092.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.