TAMPA, FL ·
OSHA Inspection: QUAD/GRAPHICS MARKETING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QUAD/GRAPHICS MARKETING, LLC in 4646 S GRADY AVENUE, TAMPA, FL 33611 (NAICS 323112). OSHA activity number 339171944.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUAD/GRAPHICS MARKETING, LLC
- Site address
- 4646 S GRADY AVENUE
- City
- TAMPA
- State
- FL
- ZIP
- 33611
- Mailing
- 4646 S GRADY AVENUE, TAMPA, FL 33611
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323112
- Employees
- 140
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Aug 1, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) As observed on or about 07/02/2013, no evidence of periodic inspections were available.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.179 G01 V
- Issued
- Aug 1, 2013
- Abate by
- Aug 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control boxes were not clearly marked for identification of functions. (a) The functions of the Telemecanique pendant of the in-feeder splicer hoist of presses 901 and 902 were not identified.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Quad/Graphics Marketing, LLC
View Quad/Graphics Marketing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 323112)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339171944.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.