PROSPECT HEIGHTS, IL —
OSHA Inspection: W.B.R. ROOFING COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of W.B.R. ROOFING COMPANY, INC. in 1241 N. RAND ROAD, PROSPECT HEIGHTS, IL 60070 (NAICS 238160). OSHA activity number 339223711.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- W.B.R. ROOFING COMPANY, INC.
- Site address
- 1241 N. RAND ROAD
- City
- PROSPECT HEIGHTS
- State
- IL
- ZIP
- 60070
- Mailing
- 25084 W. OLD RAND ROAD, WAUCONDA, IL 60084
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.502 D15
- Issued
- Aug 28, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $5,390 · Current $3,773 Reduced
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) Fall protection was anchored to a hole in a piece of sheet metal on a Carrier HVAC roof mounted unit that was not designed by Carrier to be used for personal fall protection or to support at least 5,000 pounds of force. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3773
- — Z (S) $5390
1926.502 D16 III
- Issued
- Aug 28, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) Employees were exposed to the hazard of free falling more than 6 feet and contacting a lower level while using personal fall arrest systems that were not rigged to prevent these hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B04 I
- Issued
- Aug 28, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $5,390 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels by personal fall arrest systems, covers or guardrail systems erected around such holes: a) Employees were exposed to the hazard of falling approximately 23 feet through unprotected skylights located throughout to roof deck work area. b) Employees were exposed to the hazard of falling approximately 23 feet through unprotected holes on the roof deck. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $5390
More inspections at W.B.R. Roofing Company, INC.
View W.B.R. Roofing Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339223711.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.