GRIFFIN, GA ·
OSHA Inspection: NORCOM, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORCOM, INC. in 200 BOYD'S CROSSING ROAD, GRIFFIN, GA 30224 (NAICS 322233). OSHA activity number 339226672.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORCOM, INC.
- Site address
- 200 BOYD'S CROSSING ROAD
- City
- GRIFFIN
- State
- GA
- ZIP
- 30224
- Mailing
- 200 WILSON ROAD, GRIFFIN, GA 30223
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322233
- Employees
- 200
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.37 B05
- Issued
- Sep 17, 2013
- Abate by
- Sep 24, 2013
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) At doors in the Raw Materials area leading to storage room- The employer did not mark non exit doors, exposing employees to fire hazards. b) At doors in the Raw Materials area leading to main office- The employer did not mark non exit doors, exposing employees to fire hazards.
Recent events (3)
- · J (S) $1620
- · C (S) $2700
- · Z (S) $2700
1910.147 C06 I
- Issued
- Sep 17, 2013
- Abate by
- Oct 11, 2013
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Facility- The employer did not conduct an annual inspection of the energy control procedures exposing employees to injuries due to not following proper procedures.
Recent events (3)
- · J (S) $1620
- · C (S) $2700
- · Z (S) $2700
1910.305 G01 IV A
- Issued
- Sep 17, 2013
- Abate by
- Sep 24, 2013
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cord was used as a substitute for the fixed wiring of a structure: a) Facility- The employer used an extension cord in lieu of permanent wiring, exposing employees to shock or fire hazards.
Recent events (3)
- · J (S) $1620
- · C (S) $2700
- · Z (S) $2700
More inspections at Norcom, INC.
View Norcom, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322233)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339226672.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.