Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUKE AIR FORCE BASE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUKE AIR FORCE BASE in METAL TECHNOLOGY DIVISION/SQUADRON, GLENDALE LUKE AFB, AZ 85309 (NAICS 928110). OSHA activity number 339227845.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luke AIR Force Base — free Get an email when a new federal OSHA severe-injury report for Luke AIR Force Base is published. One employer, no account, unsubscribe in one click.
Establishment
LUKE AIR FORCE BASE
Site address
METAL TECHNOLOGY DIVISION/SQUADRON
City
GLENDALE LUKE AFB
State
AZ
ZIP
85309
Mailing
14440 W. STARFIGHTER ST., BLDG 918/912, LUKE AFB, AZ 85309
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
46
Ownership type
D

7 citations on file for this inspection.

1910.37 B02

Serious Gravity 5 1 instance 46 exposed
Issued
Sep 26, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit" :   a)    Luke Air Force Base, Metal Technology Division: On July 16, 2013, and at times prior thereto, the metal shop supply room exit door leading to an outdoor location was not marked with a sign reading "Exit.  The lack of an appropriate exit door sign exposed workers to potential emergency evacuation hazards including safe egress in the event of a fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Serious Gravity 5 1 instance 46 exposed
Issued
Sep 26, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):  Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a) Luke Air Force Base, Metal Technology Division shop: On July 16, 2013,  at times prior thereto, portable fire extinguishers in the welding booth and next to the main loading gate were blocked, not properly mounted, and not readily accessible exposing workers to serious fire injuries or death in the event of an emergency.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 10 exposed
Issued
Sep 26, 2013
Abate by
Nov 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a) Luke Air Force Base, Metal Technology Division: On July 16, 2013, and at times prior thereto, the guard on the Herr-Voss Power Squaring Sheer had an inadequate barrier guard where the height of the weighted rollers guards was 1 1/4 inches and the distance of the point of operation hazard at 1 1/2 inches. Table 0-10 of OSHA 29 CFR 1910.217 states that for openings of 1 1/4 inches, the distance from the guard to the point of operation shall be 7 1/2 to 12 1/2 inches.   The guard is equipped with gravity based moveable rollers that lift easily to 1 1/14 inches.  They are not fixed and do not provide protection from hands entering past the roller guards, exposing workers to the point of operation.  No other method of machine guarding was provided.  Employees are exposed to potential hand and finger amputation hazards when feeding smaller size materials through the weighted rollers of the machine guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.265 C09 I

Serious Gravity 5 1 instance 46 exposed
Issued
Sep 26, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.265(c)(9)(i): Illumination was not provided and designed to supply adequate general and local lighting to rooms, buildings, and work areas during the time of use:   a)      Luke Air Force Base, Metal Technology Division Shop: On July 16, 2013, and at times prior thereto, the lamp on the ROMI to Tooling Machine was defective and not in working order.  The lamp provides local additional safety illumination to the work area and process.   Employees are exposed to amputation and other point of operation hazards due to a lack of adequate local lighting during the use of the retooling machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 46 exposed
Issued
Sep 26, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i):  Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a) Luke Air Force Base, Metal Technology Division: On July 16, 2013, and at times thereto, electrical boxes in the hanger and metal machine shop were not securely closed nor fastened by a suitable cover and thus exposed employees to electrocution hazards through accidental contact to live electrical wires.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Other-than-serious 1 instance 12 exposed
Issued
Sep 26, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5):     The path to ground from circuits, equipment, and enclosures was not permanent, continuous and effective.    a) Luke Air Force Base, Metal Technology Division: On July 16, 2013, and at times prior thereto, the Industrial Vacuum Cleaner (AG200) was missing a ground prong exposing workers to accidental electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 10 exposed
Issued
Sep 26, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):     The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace:    a)    Luke Air Force Base, Metal Technology Division: On July 16, 2013, and at times prior thereto, the employer could not produce a material safety data sheet for QuinSyn-Plus compressor lubricant.  The use or accidental spill and clean-up of the material exposes workers to irritation of mucous membranes and the upper respiratory tract.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Luke AIR Force Base's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339227845.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.