Unprogrammed Other inspection · Health discipline

On , OSHA opened an unprogrammed Other health inspection of U.S. DEPARTMENT OF VETERANS AFFAIRS - VA LOMA LINDA HEALTHCARE SYSTEM in 11201 BENTON STREET, LOMA LINDA, CA 92357 (NAICS 923140). OSHA activity number 339249260.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Veterans Affairs - VA Loma Linda Healthcare System — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Veterans Affairs - VA Loma Linda Healthcare System is published. One employer, no account, unsubscribe in one click.
Site address
11201 BENTON STREET
City
LOMA LINDA
State
CA
ZIP
92357
Mailing
11201 BENTON STREET, LOMA LINDA, CA 92357
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
923140
Employees
3100
Ownership type
D

10 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers was not provided, used, and/or maintained:  At the establishment - On or about 8/1/2013, and times prior thereto, the employer did not provide respiratory devices and protective clothing to facilities maintenance workers where there was exposure to bloodborne pathogens.
Recent events (1)
  • — Z (S) $0

1910.141 G02

Serious Gravity 10 4 instances 6 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.141(g)(2): Employees were permitted to consume food or beverage in area(s) exposed to toxic materials:  a) Mechanical room 1D-01 - On or about 8/1/2013, employees were permitted to consume food or beverages in areas exposed to corrosives and bloodborne pathogens.  b) Fire pump room 1D-01B - On or about 8/1/2013, employees were permitted to consume food or beverages in areas exposed to corrosives.  c) Mechanics shop - On or about 8/1/2013, employees were permitted to consume food or beverages in areas exposed to blood borne pathogens and heavy metal dusts from shop processes.  d) Paint shop, paint booth room - On or about 7/16/2013, employees were permitted to consume beverages in areas exposed to toxic material.
Recent events (1)
  • — Z (S) $0

1910.305 J02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:   Autopsy room - On or about 8/1/2013, and times prior thereto, a receptacle near a sink area was not GFCI protected.
Recent events (1)
  • — Z (S) $0

1910.1030 D02

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(d)(2): Engineering and Work Practice Controls were not used to eliminate or minimize employee exposure and/or, where occupation exposure remained after institution of these controls, personal protective equipment were not used:  TB Room 4F-01H - On or about 8/1/2013, and at times prior thereto, secondary barriers to minimize employee exposure were not implemented. A Class II A Biosafety Cabinet was not ducted to the exhaust system and exhaust air was recirculated.
Recent events (1)
  • — Z (S) $0

1910.1030 G02 II A

Serious Gravity 5 3 instances 7 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(g)(2)(ii)(A): The employer did not ensure that training was provided to employees with occupational exposure at the time of initial assignment to tasks where occupational exposure might take place:   a) Patient isolation rooms - On or about 8/1/2013, and times prior thereto, maintenance mechanics and HVAC technicians were not provided training at the time of initial assignment where occupational exposure to bloodborne pathogens can take place while conducting maintenance activities inside patient isolation rooms.    b) Mechanics shop - On or about 8/1/2013, and times prior thereto, maintenance mechanics were not provided training at the time of initial assignment where occupational exposure to bloodborne pathogens can take place while repairing and maintaining patient beds.    c) Mechanical room 1D-01 - On or about 8/1/2013, and times prior thereto, maintenance mechanics were not provided training at the time of initial assignment where occupational exposure to bloodborne pathogens can take place while repairing and maintaining dental vacuum lines.
Recent events (1)
  • — Z (S) $0

1910.1030 G02 VI

Serious Gravity 5 2 instances 7 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(g)(2)(vi): Material appropriate in content or vocabulary to educational level, literacy, or language of employees was not used in the bloodborne pathogen training program:   a) Mechanics shop - On or about 8/1/2013, and times prior thereto, maintenance mechanics were not provided training with appropriate content for their job description and educational level.   b) HVAC shop - On or about 8/1/2013, and times prior thereto, maintenance mechanics were not provided training with appropriate content for their job description and educational level.
Recent events (1)
  • — Z (S) $0

1910.1048 I02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1048(i)(2): When employees' skin could have become splashed with solutions containing 1 percent or greater formaldehyde, the employer did not provide conveniently located quick drench showers and/or did not ensure that affected employees used these facilities immediately:  Formalin pouring area near autopsy suite - On or about 8/1/2013, and times prior thereto, the employer did not provide conveniently located quick drench shower.
Recent events (1)
  • — Z (S) $0

1910.1048 I03

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1048(i)(3): When there was a possibility that an employee's eyes could be splashed with solutions containing 0.1 percent or greater formaldehyde, the employer did not provide acceptable eyewash facilities within the immediate work area for emergency use:   Formalin pouring area near autopsy suite - On or about 8/1/2013, and times prior thereto, the employer did not provide an emergency eyewash in the immediate area.
Recent events (1)
  • — Z (S) $0

1910.1200 F05 I

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  Mechanical room 1D-01 - On or about 8/1/2013, and times prior thereto, a spray bottle was not labeled with its chemical contents.
Recent events (1)
  • — Z (S) $0

1910.1200 G08

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2013
Abate by
Oct 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace:  HVAC room - On or about 7/16/2013, and times prior thereto, there was no MSDS available for ACC acid coil cleaner.
Recent events (1)
  • — Z (S) $0

View U.S. Department of Veterans Affairs - VA Loma Linda Healthcare System's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339249260.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.