OSHA Inspection: TOWER ROOFING CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TOWER ROOFING CO., INC. in 201 CANTIGNEY STREET CORNING HIGH SCHOOL, CORNING, NY 14830 (NAICS 238160). OSHA activity number 339304636.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tower Roofing CO., INC. — free Get an email when a new federal OSHA severe-injury report for Tower Roofing CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
201 CANTIGNEY STREET CORNING HIGH SCHOOL
City
CORNING
State
NY
ZIP
14830
Mailing
2009 EAST MAIN STREET, ENDWELL, NY 13760
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
15
Ownership type
A

7 citations on file for this inspection.

1926.150 C01 I

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 25, 2013
Abate by
Oct 7, 2013
Penalty
Initial $1,760 · Current $1,366 Reduced
29 CFR 1926.150(c)(1)(i): Travel distance from any point of the protected area to the nearest fire extinguisher exceeded 100 feet:     a) On or about 8/15/2013, On the roof:  There was no fire extinguisher provided on the roof where flammable liquids were in use and stored.       Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1366
  • — Z (S) $1760

1926.152 D02

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 25, 2013
Abate by
Oct 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.152(d)(2): A portable fire extinguisher having a rating of not less than 20-B units was not located between 25 feet and 75 feet from flammable liquid storage area(s) located outside:  a) On or about 8/15/2013, On the roof:  There was no fire extinguisher provided on the roof where flammable liquids were in use and stored.     Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 25, 2013
Abate by
Oct 7, 2013
Penalty
Initial $2,200 · Current $1,706 Reduced
29 CFR 1926.404(b)(1): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors:     a) On or about 8/15/2013, On the roof:  Employees were using power tools energized through extension cords.  There was no ground fault circuit interrupters in use.        Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1706
  • — Z (S) $2200

1926.501 B01

Serious Gravity 10 2 instances 8 exposed
Issued
Sep 25, 2013
Abate by
Oct 7, 2013
Penalty
Initial $3,080 · Current $2,390 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:     a) On or about 8/15/2013, Morning access to the new roof:  There was no guardrail system for the open sided surface at the base of the ladder from the roof to the second floor.          b) On or about 8/15/2013, North Access to the new roof:  There was no guardrail system in place by the ladder access point.        Abatement documentation is required for this item.
Recent events (2)
  • — I (S) $2390
  • — Z (S) $3080

1926.502 F01 III

Serious Gravity 10 1 instance 8 exposed
Issued
Sep 25, 2013
Abate by
Oct 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:   a) On or about 8/15/2013, On the new roof:  There was no warning lines between the work area and the ladder access being used.        Abatement documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1051 A

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 25, 2013
Abate by
Oct 7, 2013
Penalty
Initial $2,200 · Current $1,706 Reduced
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:     a) On or about 8/15/2013, North end of new roof:  Employees were accessing a steel erection area to a new roof area via a change in elevation of approximately 30 inches.      Abatement documentation is required for this item.
Recent events (2)
  • — I (S) $1706
  • — Z (S) $2200

1926.501 B10

Repeat Gravity 5 2 instances 10 exposed
Issued
Sep 25, 2013
Abate by
Oct 7, 2013
Penalty
Initial $11,000 · Current $7,000 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:     a) On or about 8/15/2013, Existing roof:  Employees performing roofing work on a roof with a minimum width of 72 feet were not utilizing a warning line system or physical fall protection.              b) On or about 8/15/2013, New roof:  Employees walking on a roof, with a minimum width of over 200 feet, outside of a warning line system were not protected by the use of a warning line system or a physical fall protection system.            Abatement documentation is required for this item.     The Tower Roofing Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(10), which was contained in OSHA inspection number 314101916, citation number 1, item number 3 and was affirmed as a final order on 9/15/2011, with respect to a workplace located at 46 West Main Street, Friendship, NY.     The Tower Roofing Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(11), which was contained in OSAH inspection number 314530247, citation 2, item 1 and was affirmed as a final order on 9/29/2011, with respect to a workplace located at 46 West Main Street, Friendship, NY.
Recent events (2)
  • — I (R) $7000
  • — Z (R) $11000