PUEBLO, CO —
OSHA Inspection: AMERICAN IRON & METAL
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN IRON & METAL in 1801 S. LACROSSE, PUEBLO, CO 81006 (NAICS 423930). OSHA activity number 339352569.
Where did this inspection happen?
- Establishment
- AMERICAN IRON & METAL
- Site address
- 1801 S. LACROSSE
- City
- PUEBLO
- State
- CO
- ZIP
- 81006
- Mailing
- 1801 S. LACROSSE, PUEBLO, CO 81006
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 22
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $2,380 · Current $1,500 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing injuries: a) On or about August 23, 2013, and at times prior, the employer did not ensure employees were safe from crushing hazards from a tipping retaining wall made of stacked cement blocks in the ferrous sorting area where fluff falls to the ground from a conveyor and where employees must walk and operate skid steers to remove the fluff. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1500
- — Z (S) $2380
1910.303 B02
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $1,785 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or about August 22, 2013, and at times prior, the employer did not protect employees from fire hazards in that relocateable power taps in the non-ferrous building were not properly mounted, connected to extension cords, and overloaded. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1000
- — Z (S) $1785
1910.305 A02 X
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: a) On or about August 22, 2013, and at times prior, employees were not protected from electrical hazards in that extension cord used to power the refrigerator in the lunch room in the non-ferrous building had a knot tied in it. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.29 B01
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(b)(1): A log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent), was not completed in the detail required by the regulation: (a) On or about August 23, 2013, and at times prior, the employer did not record information on the OSHA 300 log for the 2013 calendar year in the detail required in that case number 1301 was missing the object/substance that directly injured or made the person ill in column F. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.23 C01
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent): a) On or about August 22, 2013, and at times prior, the employer did not ensure that employees were protected from fall hazards of 4 feet and 6.25 inches at the loading dock north of the non-ferrous building. b) On or about August 23, 2013, and at times prior, the employer did not ensure that employees were protected from fall hazards of greater than 4 feet at the shaker tables near the picking station. c) On or about August 23, 2013, and at times prior, the employer did not ensure that employees were protected from a fall hazard of 4 feet and 2 inches into the window well on the west side of the office building. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.23 D01
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1): Flights of stairs having four or more risers were not equipped with a standard railing as specified in paragraphs (d)(1)(i) through (v) of this section: c) On or about August 23, 2013, and at times prior, the employer did not ensure that employees were protected from a fall hazard from the flight of stairs outside along the north wall of the office building that has 7 risers in that did not have a railing. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 A03
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) On or about August 22, 2013, and at times prior, the exit door on the west wall on the south end of the non-ferrous building was blocked with debris. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) On or about August 23, 2013, and at times prior, the employer did not certify that operators of the various material handling equipment including skid steers, had been trained and evaluated by documenting the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.180 D06
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.180(d)(6): Monthly, dated and signed inspection records and reports for truck crane(s) were not provided for critical items such as (but not limited to) brakes, crane hooks and ropes: a) On or about August 23, 2013, and at times prior, inspection records on the CAT Material Handler cranes were not kept and readily available. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Oct 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about August 22, 2013, and at times prior, the employer did not ensure that employees were protected from fire hazards in that the electrical panels in the electrical room in the non-ferrous building were blocked from access by stored items.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) On or about August 22, 2013, and at times prior, the employer did not ensure that employees were protected from electrical hazards along the south wall of the non-ferrous building in that an outlet that was energized did not have a faceplate. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Oct 28, 2013
- Abate by
- Nov 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) On or about August 23, 2013, and at times prior, the employer did not ensure employees were protected from a fire hazard on electrical box for the actuators and interlocks on the Ten Sixty bailer in the can shack, where the wiring was not protected at the fitting with shielding to prevent strain on the wiring. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at American Iron & Metal
View American Iron & Metal's full OSHA safety record →