BEAR CREEK, WI —
OSHA Inspection: GLK FOODS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GLK FOODS, LLC in 400 CLARK STREET, BEAR CREEK, WI 54922 (NAICS 311421). OSHA activity number 339361230.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLK FOODS, LLC
- Site address
- 400 CLARK STREET
- City
- BEAR CREEK
- State
- WI
- ZIP
- 54922
- Mailing
- P.O. BOX 217, BEAR CREEK, WI 54922
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311421
- Employees
- 153
- Ownership type
- A
Citations
24 citations on file for this inspection.
1910.23 A05
- Issued
- Oct 10, 2013
- Abate by
- Oct 21, 2013
- Penalty
- Initial $4,950 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.23(a)(5): Every pit and floor opening was not adequately guarded by standard railing or any other effected means. a) Waste water screen room had two open pits approximately 6 feet deep that were not guarded adequately. b) Flow meter room had an open pit approximately 5 feet deep that was not guarded adequately at the time of the inspection. Grating was lowered to cover this opening during the walk-a-round. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $2475
- — C (S) $4950
- — Z (S) $4950
1910.23 A08 II
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(a)(8)(ii): Every floor hole into which persons can accidentally walk were not guarded by a floor hole cover of standard strength and construction: a) Vat room aisle by vats 64 & 65 had floor holes that were not guarded. One was approximately 6" x 6" and the second was approximately 2" x 24". b) Core machine area, Approximately 8 1/2" gap along wall to vats. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.23 C03
- Issued
- Oct 10, 2013
- Abate by
- Mar 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board. a) Salt dispenser landing had platforms on them which were approximately 8 1/2" high which rendered the standard 42" guard rails inadequate. b) Vat #54 and the other ones in the room had walls on the aisles that were approximately 24" high rather then 42" as required by the standard. c) No toeboard for 11'6" section of railing by vacuum pump platform with a fall distance of approximately 102". d) Open gate blocked open by hose exposing employees to 102" fall hazard while dumping 5 gallon waste pails of kraut into hopper below. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.24 F
- Issued
- Oct 10, 2013
- Abate by
- Mar 15, 2015
- Penalty
- Initial $5,940 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs: a) West stairs from cutting line were not uniform throughout with a variation from 6 1/2" to 10 3/4". b) Palletizer steps were not uniform throughout with a variation from 7 1/2" to 12". ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $2970
- — C (S) $5940
- — Z (S) $5940
1910.27 D02 III
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $4,950 · Current $0 Reduced
General-duty citation text
29 CFR 1910.27(d)(2)(iii): One rung of any section of ladder was not located at the level of the landing laterally served by the ladder, and where access to the landing was through the ladder the same rung spacing as used on the ladder was not used from the landing platform to the first rung below the landing. a) Top rung of the vertical ladder was not located at the platform level for the upper platform on the waste leaf hopper equipment. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $4950
- — Z (S) $4950
1910.27 D03
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $2,475
General-duty citation text
29 CFR 1910.27(d)(3): The employer did not ensure that the side rails of a through ladder extended 3 1/2 feet above parapets and landings, omitting the rungs from the extension and having not less than 18 nor more than 24 inches clearance between the rails. a) No side rails were provided for the upper platform vertical ladder on the waste leaf hopper equipment. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $2475
- — C (S) $0
- — Z (S) $0
1910.37 A03
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $4,950 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Exit door behind conveyor frame work had a damaged door knob and would not open in an emergency along wall near label liner for cans. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $2475
- — C (S) $4950
- — Z (S) $4950
1910.133 A01
- Issued
- Oct 10, 2013
- Abate by
- Oct 25, 2013
- Penalty
- Initial $5,940 · Current $0 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On or about 8/28/2013, employee cutting grass beside roadway with riding lawnmower was not wearing safety glasses exposing employee to injury from flying objects. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $5940
- — Z (S) $5940
1910.146 C01
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $4,950 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a) On or about 8/27/2013 employees entered vat #54 without evaluation data to indicate that the vat was not a permit required confined space. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
- — F (S) $2475
- — C (S) $4950
- — Z (S) $4950
1910.151 C
- Issued
- Oct 10, 2013
- Abate by
- Mar 15, 2015
- Penalty
- Initial $3,960 · Current $1,980 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about 8/28/2013, employee operating on platform with kraut conveyor and chemical tank did not have access to an emergency shower eye wash station. Chemicals added from platform included Sodium Metabisulfite, Sodium Benzoate, and Purac FCC 88 (lactic acid). ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $1980
- — C (S) $3960
- — Z (S) $3960
1910.212 A01
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $6,930 · Current $3,465 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 8/27/2013, there was an unguarded auger in a trough along the east wall of the cutting line with an employee cleaning in the area of an approximately 12" x 9" opening. c) On or about 8/27/2013, there was an unguarded belt nip on the west end of the uncore conveyor with an approximate 5" gap approximately 4 1/2" from the frame of the conveyor. d) On or about 8/27/2013, there were several rusted out fan blade covers on core machine motors approximatly 76" from the floor on both sides of the return uncore conveyor. e) On or about 8/27/2013, there was an ingoing nip point on the transfer conveyor to room 6. f) On or about 8/27/2013, there was an unguarded area on the core machine approximately 36" wide x 15" to 24" high allowing access to the spinning cutter. g) On or about 8/27/2013, the Wilton horizontal bad saw in the maintenance shop did not have the unused portion of the blade guarded with approximatley 5" exposed. h) On or about 8/28/2013, the Balemaster micro switch was stuck and did not prevent compacting with the guard door open. Repaired by maintenance at time of inspection. i) On or about 8/28/2013, there was an auger in the waste leaf trough on a platform outside of the building that needed guarding in two locations. It was approximately 24" to the nip point from the railing on the platform. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $3465
- — C (S) $6930
- — Z (S) $6930
1910.219 C02 I
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $5,940 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) On or about 8/27/2013, approximately 3" of trash auger drive shaft was not guarded where an employee was reaching down to cleanup around motor and drive unit. b) On or about 8/27/2013, drive shaft was exposed for upper transfer coring line conveyor. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $2970
- — C (S) $5940
- — Z (S) $5940
1910.219 F01
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a) On or about 8/28/2013, the east end of the small can filler machine was missing the guard which protects the gears approximately 6" inside of outer frame. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) On or about 8/28/2013, glass depaletizer 01130 guard not secured exposing chain and sprocket beside catwalk near control panel. Approximately 2" to ingoing nip point from out of place guard. b) On or about 8/28/2013, caser for cans off lable line did not have the chain and sprocket drive guarded at floor level where cans are cleaned up that come off line. c) On or about 8/28/2013, waste water screem room screw conveyor did not have the chain and sprocket drive guarded. ABATEMENT CERTIFICATION REQUIRED FOR "b)"
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 I02
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(i)(2): Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve: a) On or about 8/27/2013, #1 salt dispenser had an unguarded coupling approximately 6" wide. #2 salt dispenser coupling also needed guarding. b) On or about 8/28/2013, drive shaft coupling for kraut conveyor was not guarded on platform feeding equipment where chemicals are mixed and added. c) On or about 8/28/2013, drive shaft coupling for glass depalletizer skid conveyor was not guarded approximately 18" from the aisle beside the equipment. d) On or about 8/28/2013, Drive shaft coupling for auger on waste leaf hopper platform was not guarded approximately 15" inside of platform. ABATEMENT CERTIFICATION REQUIRED FOR a & b
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Oct 10, 2013
- Abate by
- Feb 28, 2014
- Penalty
- Initial $2,970 · Current $1,485 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 8/28/2013, air hoses that were available for cleaning at the end of each shift had approximatley 120 p.s.i. as measured on the line gauge near the air hose. The two air hoses were located by the can lable line and did not have pressure reducing air wands. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $1485
- — C (S) $2970
- — Z (S) $2970
1910.303 F02
- Issued
- Oct 10, 2013
- Abate by
- Oct 25, 2013
- Penalty
- Initial $4,950 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) On or about 8/27/2013, VAT Room #7 contained a 480 volt electrical panel with a disconnect that was not labled to indicate its purpose along the south wall. b) On or about 8/28/2013, Production room SE corner contained an electrical panel with two power supply disconnects that were not labeled to indicat their purpose. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $2475
- — C (S) $4950
- — Z (S) $4950
1910.305 A02 I
- Issued
- Oct 10, 2013
- Abate by
- Oct 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners:Note: Temporary electrical power and lighting installation(s) may only be used as specified by 1910.305(a)(2)(i)(A) through 1910.305(a)(2)(i)(C). a) On or about 8/28/2013, Temporary power cords were being used to supply power to tray sealer and air curtain near the depalletizer area. b) On or about 8/28/2013, Temporary power cord was being used to supply power to electrical junction box for truck heater electrical cords outside of Vat Room #5. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.305 B01 I
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) On or about 8/28/2013, temporary power cord coming out of the circuit breaker box for the tray sealer was not protected with a fitting at the knockout hole. b) On or about 8/28/2013, depalletizer flex conduit was separated exposing live wiring to micro switch on glass jar conveyor. ABATEMENT CERTIFICATION REQUIRED FOR "b"
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- Oct 10, 2013
- Abate by
- Oct 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a) On or about 8/28/2013, a temporary cord was used to supply power to a diesel pump that had a splice in it that was not protectedor insulated. NO ABATEMENT CERTIFICATION REQUIRED.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 F05 I
- Issued
- Oct 10, 2013
- Abate by
- Oct 25, 2013
- Penalty
- Initial $3,960 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) On or about 8/28/2013, a 55 gallon drum was sitting in the waste water screen room with limited information on it as to its contents. (Concentrate Advance Roundup Weedkiller) ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (O) $0
- — C (S) $3960
- — Z (S) $3960
1910.1200 F05 II
- Issued
- Oct 10, 2013
- Abate by
- Oct 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a) On or about 8/28/2013, a 55 gallon drum was sitting in the waste water screen room with limited information on it as to its contents. No hazard warning label on drum. (Concentrate Advance Roundup Weedkiller) ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.147 D03
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $9,900 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) On or about 8/28/2013, Maintenance person working on Can label line locked out electrical control button rather then the machine disconnect. GREAT LAKES KRAUT CO LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1910.147(d)(3) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 669638, CITATION NUMBER 01, ITEM NUMBER 004 a AND WAS AFFIRMED AS A FINAL ORDER ON 03/08/2013, WITH RESPECT TO A WORKPLACE AT 400 CLARK STREET, BEAR CREEK, WI 54922 ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
- — F (S) $2970
- — C (R) $9900
- — Z (R) $9900
1910.22 D01
- Issued
- Oct 10, 2013
- Abate by
- Nov 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. a) Storage area above Chemical room did not have the load limits posted. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at GLK Foods, LLC
View GLK Foods, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311421)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339361230.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.