SAN ANTONIO, TX —
OSHA Inspection: HARLAND CLARKE CORP.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HARLAND CLARKE CORP. in 5003 STOUT DR, SAN ANTONIO, TX 78219 (NAICS 322233). OSHA activity number 339392763.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARLAND CLARKE CORP.
- Site address
- 5003 STOUT DR
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78219
- Mailing
- 5003 STOUT DR, SAN ANTONIO, TX 78219
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322233
- Employees
- 4000
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.106 E02 II
- Issued
- Jan 16, 2014
- Abate by
- Jan 29, 2014
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii): Flammable or combustible liquids were not stored in tanks or closed containers: a) Web 2: On or about September 5, 2013, employees were exposed to the hazards of fire or inhalation of flammable vapor when met wash was left open in a flammable cabinet. b) Web 2: On or about September 5, 2013, employees were exposed to the hazards of fire or inhalation of flammable vapor when R-7, plate cleaner was left open in a flammable cabinet. c) Web 20: On or about September 5, 2013, employees were exposed to the hazards of fire or inhalation of flammable vapor when met wash was left open in a flammable cabinet. d) Web 20: On or about September 5, 2013, employees were exposed to the hazards of fire or inhalation of flammable vapor when met wash was left open in a flammable cabinet.
Recent events (2)
- — I (O) $1800
- — Z (S) $3000
1910.303 B02
- Issued
- Jan 16, 2014
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about September 5, 2013, employees were exposed to electrical shock of 115 volts when a Syntron Jogger, UL 875A, was plugged into a relocatable power tap or power strip that did not have a label. b) On or about September 5, 2013, employees were exposed to electrical shock of 110 volts when a Plate Position Verification Indicator, was plugged into a relocatable power tap or power strip that did not have a label.
Recent events (2)
- — I (O) $2400
- — Z (S) $4000
1910.305 G01 IV A
- Issued
- Jan 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about September 5, 2013, employees were exposed to electrical shock of 115 volts when a Syntron Jogger, UL 875A, was plugged into a relocatable power tap or power strip that was used as temporary wiring. b) On or about September 5, 2013, employees were exposed to electrical shock of 110 volts when a Plate Position Verification Indicator was plugged into a relocatable power tap or power strip that was used as temporary wiring.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.304 G05
- Issued
- Jan 16, 2014
- Abate by
- Jan 29, 2014
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about September 5, 2013, employees were exposed to electrical shock hazards of 110 volts when the grounding prong of the Burgess Industries Inc was removed and plugged into a power strip.
Recent events (2)
- — I (S) $2400
- — Z (S) $4000
More inspections at Harland Clarke Corp.
View Harland Clarke Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 322233)
More inspections in TX
Source