CORPUS CHRISTI, TX —
OSHA Inspection: SAM KANE BEEF PROCESSORS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SAM KANE BEEF PROCESSORS, LLC in 9001 LEOPARD ST, CORPUS CHRISTI, TX 78409 (NAICS 424470). OSHA activity number 339413684.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAM KANE BEEF PROCESSORS, LLC
- Site address
- 9001 LEOPARD ST
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78409
- Mailing
- PO BOX 9254, CORPUS CHRISTI, TX 78469
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424470
- Employees
- 761
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.119 D03 II
- Issued
- Mar 5, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $3,300 · Current $1,650 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices: a) The Employer failed to ensure that the U1 data or its equivalent and name plates were maintained and available for vessels: 1. (VLR-1) Accumulator/Recirculator in engine room #1 2. (VDT-1) Dump Tank in engine room #1 3. (HPR-1) high Pressure Receiver for engine room #1 4. (VLR-2) Recirculator in engine room #1 5. (HPR-2) High Pressure Receiver in engine room #2
Recent events (2)
- — I (S) $1650
- — Z (S) $3300
1910.119 E01
- Issued
- Mar 5, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $5,500 · Current $2,750 Reduced
General-duty citation text
29 CFR 1910.119(e)(1): The process hazard analysis was not appropriate to the complexity of the process and did not identify, evaluate, and control the hazards involved in the process: At this facility, the process hazard analysis was not appropriate to the complexity of the process and did not identify, evaluate, and control the hazards associated with allowing safety relief valves (SRV) to relieve to the atmosphere in locations occupied by employees, including but not limited to: a) The parking lot next to engine room #1 and 2, b) The medical trailer next to engine room #1 and c) The road way inside the fence line next to engine room #2.
Recent events (2)
- — I (S) $2750
- — Z (S) $5500
1910.119 J02
- Issued
- Mar 5, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish and implement written procedures to maintain the on-going integrity of process equipment: The employer did not develop and implement mechanical integrity program procedures for the inspection testing and repairing of insulated Ammonia Refrigeration process vessels and piping. This hazard was observed in Engine Rooms #1 & 2, where the employer continued to operate vessels and piping that had damaged and or missing insulation.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.119 J04
- Issued
- Mar 5, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(4): Inspection and testing was not performed on process equipment: The employer did not inspect and test insulated Ammonia Refrigeration process vessels and piping. This hazard was observed in Engine Room #2, when the employer allowed vessels and piping to continue to operate with damaged and or missing insulation without inspecting and testing the system for damaged insulation and or potential leaks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 J05
- Issued
- Mar 5, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that are outside acceptable limits (defined by the process safety information in paragraph (d) of this section) before further use or in a safe and timely manner when necessary means are taken to assure safe operation: The employer did not correct deficiencies in Ammonia Refrigeration process equipment, in that the employer continued to operate vessels and piping in engine Room #2 without repairing the insulation and ensuring that large ice deposits on the surfaces were not due to anhydrous ammonia leaks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at SAM Kane Beef Processors, LLC
View SAM Kane Beef Processors, LLC's full OSHA safety record →
More inspections in this industry (NAICS 424470)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339413684.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.